Electric Power Generation

Commercial and Industrial Generators

Any size or shape. In any regulatory environment. When you need power, Caterpillar is equal to the challenge. Our commercial and industrial generators are used in a variety of applications.

To help find the right generator set for your regional needs use our NEW “Country of Use” selection facet.

Diesel Generator Sets

From 6 to 14,040 ekW (7.5 to 17,550 kVA) of power potential, our diesel-fueled generator sets are built to world-class standards, for high efficiency, low fuel consumption and global emissions compliance. Generator sets come in a range of options to match your power needs, making selecting and installing simple. Discover power designed for your demands.

C1.1 (60 Hz)

C1.1
  • Minimum Rating
    8.0 ekW
  • Maximum Rating
    8.8 ekW
  • Emissions/Fuel Strategy
    EU Stage IIIA
View model

C1.5 (50 Hz)

C1.5
  • Minimum Rating
    10.0 kVA
  • Maximum Rating
    13.5 kVA
  • Emissions/Fuel Strategy
    EU Stage IIIA
View model

C1.5 (60 Hz)

C1.5
  • Minimum Rating
    12.0 ekW
  • Maximum Rating
    13.2 ekW
  • Emissions/Fuel Strategy
    EU Stage IIIA
View model

C2.2 (60 Hz)

C2.2
  • Minimum Rating
    15.5 ekW (15.5 kVA)
  • Maximum Rating
    20.0 ekW (25.0 kVA)
  • Emissions/Fuel Strategy
    EU Stage IIIA
View model

C3.3 (60 Hz)

C3.3
  • Minimum Rating
    27.0 ekW (33.8 kVA)
  • Maximum Rating
    60.0 ekW (75 kVA)
  • Emissions/Fuel Strategy
    Non Regulated, EU Stage II and EU Stage IIIA
View model

C4.4 (60 Hz)

C4.4 Enclosure
  • Minimum Rating
    72.0 ekW
  • Maximum Rating
    100.0 ekW
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Use Only (Tier 3 Nonroad Equivalent Emission Standards)
View model

C4.4 (60 Hz)

C4.4 Enclosure
  • Minimum Rating
    36 ekW
  • Maximum Rating
    60 ekW
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Use Only (Tier 3 Nonroad Equivalent Emission Standards)
View model

C7.1 (60 Hz)

C7.1 Diesel Generator
  • Minimum Rating
    114 ekW
  • Maximum Rating
    200 ekW
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Use Only ( Tier 3 Nonroad Equivalent Emission Standards)
View model

C9 (60 Hz)

C9 Open Diesel Generating Set
  • Minimum Rating
    180 ekW
  • Maximum Rating
    300 ekW
  • Emissions/Fuel Strategy
    Low Fuel Consumption, U.S. EPA Certified for Stationary Emergency Use only ( Tier 3 Nonroad Equivalent Emission Standards)
View model

C13 (60 Hz)

C13 NACD Diesel Generator Set
  • Minimum Rating
    320 ekW
  • Maximum Rating
    400 ekW
  • Emissions/Fuel Strategy
    EPA Stationary Emergency Use
View model

C15 (60 Hz)

C15 Diesel Generator Sets
  • Minimum Rating
    320 ekW
  • Maximum Rating
    500 ekW
  • Emissions/Fuel Strategy
    Low Fuel Consumption, U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 or Tier 3 Nonroad Equivalent Emission Standards), EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards
View model

C18 (60 Hz) Tier 4

C18 Diesel Generator Set
  • Minimum Rating
    455 ekW
  • Maximum Rating
    500 ekW
  • Emissions/Fuel Strategy
    U.S. EPA Tier 4 Final
View model

C18 (60 Hz)

C18 left Rear Image
  • Minimum Rating
    455 ekW
  • Maximum Rating
    600 ekW
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)
View model

3412C (50 Hz)

3412C Diesel Generator Sets
  • Minimum Rating
    680 kVA
  • Maximum Rating
    900 kVA
  • Emissions/Fuel Strategy
    Low Fuel Consumption
View model

3412C (60 Hz)

3412C Diesel Generator Sets
  • Minimum Rating
    591 ekW
  • Maximum Rating
    800 ekW
  • Emissions/Fuel Strategy
    Low Fuel Consumption
View model

C27 (60 Hz)

C27 (60 Hz)
  • Minimum Rating
    680 ekW
  • Maximum Rating
    800 ekW
  • Emissions/Fuel Strategy
    Low Fuel Consumption, U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)
View model

C32 (60 Hz)

C32 Diesel Generator Sets
  • Minimum Rating
    830 ekW
  • Maximum Rating
    1250 ekW
  • Emissions/Fuel Strategy
    Low Fuel Consumption, Low Emissions, EPA Certified for Stationary Emergency Application (Emits Equivalent U.S. EPA Tier 2 Nonroad Standards)
View model

3512A (60 Hz)

3512A  Diesel Generator Sets
  • Minimum Rating
    890 ekW
  • Maximum Rating
    1250 ekW
  • Emissions/Fuel Strategy
    Low Fuel Consumption
View model

3512A (50 Hz) with Upgradeable Package

3512A (50 Hz) Upgradeable Package
  • Minimum Rating
    1000 kVA
  • Maximum Rating
    1400 kVA
  • Emissions/Fuel Strategy
    Low Fuel Consumption, Low Emissions
View model

3512B (60 Hz)

3512B  Diesel Generator Sets
  • Minimum Rating
    1230 ekW
  • Maximum Rating
    1500 ekW
  • Emissions/Fuel Strategy
    Low Fuel Consumption, Low Emissions
View model

3512C (60 Hz)

3512C Diesel Generator Sets
  • Minimum Rating
    1230 ekW
  • Maximum Rating
    1500 ekW
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)
View model

3512C (1750 ekW, 60 Hz)

3512C Diesel Generator Sets
  • Minimum Rating
    1750 ekW
  • Maximum Rating
    1750 ekW
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)
View model

3516A (60 Hz)

3516A Diesel Generator Sets
  • Minimum Rating
    1450 ekW
  • Maximum Rating
    1600 ekW
  • Emissions/Fuel Strategy
    Low Fuel Consumption, Low Emissions
View model

3516A (50 Hz)

3516A Diesel Generator Sets
  • Minimum Rating
    1600 kVA
  • Maximum Rating
    2000 kVA
  • Emissions/Fuel Strategy
    Low Fuel Consumption
View model

3516A (50 Hz)

3516A Diesel Generator Sets
  • Minimum Rating
    1600 kVA
  • Maximum Rating
    2000 kVA
  • Emissions/Fuel Strategy
    Low Fuel Consumption, Low Emissions
View model

3516B (50 Hz) with Upgradeable Package

3516B with Flexible Packaging
  • Minimum Rating
    1750 kVA
  • Maximum Rating
    2500 kVA
  • Emissions / Fuel Strategy
    Low fuel Consumption, Low Emissions
View model

3516B (60 Hz) with Upgradeable Package

3516B with Flexible Packaging
  • Minimum Rating
    1640 ekW
  • Maximum Rating
    2250 ekW
  • Emissions/Fuel Strategy
    Low fuel Consumption, Low Emissions
View model

3516B (50 Hz) India Market Only

3516B Diesel Generator Sets
  • Minimum Rating
    2000 kVA
  • Maximum Rating
    2000 kVA
  • Emissions/Fuel Strategy
    Low Fuel Consumption
View model

3516B (60 Hz)

3516B Diesel Generator Sets
  • Minimum Rating
    1640 ekW
  • Maximum Rating
    2250 ekW
  • Emissions/Fuel Strategy
    Low Fuel Consumption, Low Emissions
View model

3516B DGB™ (50 Hz)

3516B Diesel Generator Sets
  • Minimum Rating
    1750 kVA
  • Maximum Rating
    2275 kVA
  • Emissions/Fuel Strategy
    Low Fuel Consumption
View model

3516B DGB™ (60 Hz)

3516B Diesel Generator Sets
  • Minimum Rating
    1640 ekW
  • Maximum Rating
    1825 ekW
  • Emissions/Fuel Strategy
    Low Fuel Consumption
View model

3516B (50 Hz)

3516B Diesel Generator Sets
  • Minimum Rating
    1750 kVA
  • Maximum Rating
    2500 kVA
  • Emissions/Fuel Strategy
    Low Fuel Consumption, Low Emissions
View model

3516B (50 Hz) with Upgradeable Package

3516B Right Back
  • Minimum Rating
    2000 kVA
  • Maximum Rating
    2500 kVA
  • Emissions/Fuel Strategy
    Low Fuel Consumption, Low Emissions
View model

3516B (50 Hz) with Upgradeable Package

3516B Diesel Generator Sets
  • Minimum Rating
    1750 kVA
  • Maximum Rating
    2250 kVA
  • Emissions/Fuel Strategy
    Low Fuel Consumption, Low Emissions
View model

3516C Tier 4 Final (60 Hz)

3516C Tier 4 Interim
  • Minimum Rating
    1650 ekW
  • Maximum Rating
    2500 ekW
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Non-Emergency Stationary Genset
View model

3516C (60 Hz)

3516C Diesel Generator Sets
  • Minimum Rating
    1650 ekW
  • Maximum Rating
    2500 ekW
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards), Low Fuel Consumption
View model

3516C (50 Hz)

3516C Diesel Generator Sets
  • Minimum Rating
    2500 kVA
  • Maximum Rating
    2750 kVA
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards), Low Fuel Consumption
View model

3516C (60 Hz)

3516C Diesel Generator Sets
  • Minimum Rating
    1650 ekW
  • Maximum Rating
    2500 ekW
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards), Low Fuel Consumption
View model

3516E (50 Hz)

3516E Package Genset - Low Voltage
  • Minimum Rating
    2750 kVA
  • Maximum Rating
    3000 kVA (3100 kVA without fan)
  • Emissions/Fuel Strategy
    Low Fuel Consumption
View model

3516E (60 Hz)

3516E Package Genset
  • Minimum Rating
    2500 eKW
  • Maximum Rating
    2750 ekW
  • Emissions/Fuel Strategy
    US EPA Stationary Emergency Use Only (Tier 2)
View model

C175-16 (60 Hz)

C175-16 Diesel Generator Sets
  • Minimum Rating
    2500 ekW
  • Maximum Rating
    3100 ekW
  • Emissions/Fuel Strategy
    Low Fuel Consumption, U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)
View model

C175-16 Tier 4 Final (60 Hz)

C175-16 Tier 4 Final
  • Minimum Rating
    2500 ekW
  • Maximum Rating
    3100 ekW
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Non-Emergency Stationary Genset
View model

C175-20 (60 Hz)

C175-20 Diesel Generator Set
  • Minimum Rating
    3150 ekW
  • Maximum Rating
    4000 ekW
  • Emissions/Fuel Strategy
    Low Fuel Consumption, U.S. EPA Stationary Emergency Use Only
View model

3606 (60 Hz)

3606 Diesel Generator Set
  • Minimum Rating
    1375 ekW
  • Maximum Rating
    2000 ekW
  • Emissions/Fuel Strategy
    Low Fuel Consumption
View model

3608 (60 Hz)

3608
  • Minimum Rating
    1830 ekW
  • Maximum Rating
    2660 ekW
  • Emissions/Fuel Strategy
    Low Fuel Consumption
View model

3612 (60 Hz)

3612
  • Minimum Rating
    2750 ekW
  • Maximum Rating
    5320 ekW
  • Emissions/Fuel Strategy
    Low Fuel Consumption
View model

3616 (60 Hz)

3616
  • Minimum Rating
    3660 ekW
  • Maximum Rating
    5320 ekW
  • Emissions/Fuel Strategy
    Low Fuel Consumption
View model

Gas Generator Sets

Ranging from 20 to 9,700 ekW (25 to 12,125 kVA) in a single unit, our gas generator sets are easy to select, permit and install. They are proven for reliable operation with a wide range of gaseous fuels including natural gas, biogas from landfills and digesters, propane and alternative fuels. We build durable, low life-cycle cost power systems that we integrate with controls, exhaust systems, fuel train, combined cooling heat & power skids and switchgear.

DG50-2 (Single Phase)

DG50-2 (Single Phase)
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
View model

DG50-2 (3 Phase)

DG50-2 (3 Phase)
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
View model

DG60-2 (Single Phase)

D60-2 (Single Phase)
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
View model

DG60-2 (3 Phase)

DG60-2 (3 Phase)
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
View model

DG80-2 (Single Phase)

DG80-2 (Single Phase)
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
View model

DG80-2 (3 Phase)

DG80-2 (3 Phase)
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
View model

DG100-2S (Single Phase)

DG100-2 (Single Phase)
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
View model

DG100-2 (3 Phase)

DG100-2 (3 Phase)
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
View model

DG125-2 (3 Phase)

DG125-2 (3 Phase)
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
View model

DG150-2 (3 Phase)

DG150-2 (3 Phase)
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
View model

DG175 GC (Single-phase)

Open Generator Set
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
View model

DG175 GC (3 phase)

Open Generator Set
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
View model

DG200 GC (3 phase)

Open Generator Set
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
View model

DG200 GC (Single-phase)

Open Generator Set
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
View model

DG230 GC (3 phase)

Open Generator Set
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
View model

DG250 GC (3 phase)

Open Generator Set
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
View model

DG275 GC (3 phase)

Open Generator Set
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
View model

DG300 GC (3 phase)

Open Generator Set
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
View model

DG350 GC (3 phase)

Open Generator Set
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
View model

DG400 GC (3 phase)

Open Generator Set
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
View model

DG450 GC (3 phase)

Open Generator Set
  • Emissions/Fuel Strategy
    U.S. EPA Certified for Stationary Emergency Application
View model

G3406

G3406
  • Maximum Continuous Rating
    235 ekW
  • Fuel Type
    Natural Gas, Biogas, Field Gas, Propane
  • Maximum Electrical Efficiency
    37.30%
View model

G3408

G3408
  • Maximum Continuous Rating
    235 ekW
  • Fuel Type
    Natural Gas, Biogas, Field Gas, Propane
  • Maximum Electrical Efficiency
    37.30%
View model

CG132B-8

CG132B-8
  • Length
    122 in
  • Width
    70 in
  • Height
    85 in
View model

G3412

G3412 Left Hand Side
  • Maximum Continuous Rating
    453 ekW
  • Fuel Type
    Natural Gas, Biogas, Field Gas, Propane
  • Maximum Electrical Efficiency
    37.30%
View model

CG132B-12

CG132-12  Gas Generator Sets
  • Length
    151 in
  • Width
    70 in
  • Height
    85 in
View model

CG132B-16

CG132B-16  Gas Generator Sets
  • Length
    165 in
  • Width
    70 in
  • Height
    85 in
View model

G3512 750kW

G3512 Gas Generator Set
  • Gas Standby Rating
    750kW
  • Fuel Type
    Natural Gas
  • Emissions/Fuel Strategy
    U.S. EPA Stationary Emergency Certified
View model

G3512 1000kW

G3512 Gas Generator Set
  • Gas Standby Rating
    1000kW
  • Fuel Type
    Natural Gas
  • Emissions/Fuel Strategy
    U.S. EPA Stationary Emergency Certified
View model

G3512E

G3512E
  • Maximum Continuous Rating
    1000 ekW
  • Fuel Type
    Natural Gas
  • Maximum Electrical Efficiency
    42.20%
View model

G3512H

G3512H  Gas Generator Sets 60Hz
  • Maximum Continuous Rating
    1515 ekW / 1505 ekW
  • Fuel Type
    Natural Gas
  • Maximum Electrical Efficiency
    44.90%
View model

CG170-12

CG170-12
  • Maximum Continuous Rating
    1200 ekW
  • Fuel Type
    Natural Gas, Biogas, Coal Gas
  • Maximum Electrical Efficiency
    43.40%
View model

CG170-12 (1.0 pf)

CG170-12
  • Maximum Continuous Rating
    1000 ekW
  • Fuel Type
    Natural Gas, Biogas, Coal Gas
  • Maximum Electrical Efficiency
    43.40%
View model

CG170-12 K

CG170-12
  • Maximum Continuous Rating
    1125 ekW
  • Fuel Type
    Natural Gas, Biogas, Coal Gas
  • Maximum Electrical Efficiency
    43.40%
View model

G3516A

G3516A  Gas Generator Sets
  • Maximum Continuous Rating
    1041 ekW
  • Fuel Type
    Natural Gas, Biogas, Coal Gas
  • Maximum Electrical Efficiency
    36.40%
View model

G3516B

G3516B  Gas Generator Sets
  • Maximum Continuous Rating
    1312 ekW
  • Fuel Type
    Natural Gas
  • Maximum Electrical Efficiency
    35.50%
View model

G3516C

G3516C Gas Generator Sets
  • Maximum Continuous Rating
    1605 ekW
  • Fuel Type
    Natural Gas
  • Maximum Electrical Efficiency
    40.10%
View model

G3516E

G3516E   Gas Generator Sets
  • Maximum Continuous Rating
    1603 ekW
  • Fuel Type
    Natural Gas
  • Maximum Electrical Efficiency
    41.70%
View model

G3516H

G3516H  Gas Generator Sets
  • Maximum Continuous Rating
    2027 ekW / 2007 ekW
  • Fuel Type
    Natural Gas
  • Maximum Electrical Efficiency
    44.70%
View model

CG170-16

CG170-16 Gas Generator Sets
  • Maximum Continuous Rating
    1560kW
  • Fuel Type
    Natural Gas, Biogas, Coal Gas
  • Maximum Electrical Efficiency
    43.30%
View model

CG170-16 K

CG170-16 Gas Generator Sets
  • Maximum Continuous Rating
    1500 kW
  • Fuel Type
    Natural Gas, Biogas, Coal Gas
  • Maximum Electrical Efficiency
    43.30%
View model

G3520C

G3520C Gas Generator Sets
  • Maximum Continuous Rating
    2077 ekW
  • Fuel Type
    Natural Gas, Biogas, Coal Gas
  • Maximum Electrical Efficiency
    40.40%
View model

G3520E

G3520E Gas Generator Sets
  • Maximum Continuous Rating
    2039 ekW
  • Fuel Type
    Natural Gas
  • Maximum Electrical Efficiency
    42.40%
View model

G3520H

G3520H Gas Generator Set
  • Maximum Continuous Rating
    2519/2500 ekW
  • Fuel Type
    Natural Gas, Biogas, Coal GasNatural Gas, Biogas, Coal Gas
  • Maximum Electrical Efficiency
    45.40%
View model

CG170-20

CG170-20
  • Maximum Continuous Rating
    2000 ekW
  • Fuel Type
    Natural Gas, Biogas, Coal Gas
  • Maximum Electrical Efficiency
    43.70%
View model

CG170-20 (HE)

CG170-20
  • Maximum Continuous Rating
    2000 ekW
  • Fuel Type
    Natural Gas, Biogas, Coal Gas
  • Maximum Electrical Efficiency
    43.70%
View model

CG260-12

CG260-12
  • Maximum Continuous Rating
    3000 ekW
  • Fuel Type
    Natural Gas, Coal Gas
  • Maximum Electrical Efficiency
    43.90%
View model

CG260-16

CG260-16
  • Maximum Continuous Rating
    4000 ekW
  • Fuel Type
    Natural Gas, Biogas, Coal Gas, Associated Gas, Synthesis Gas
  • Maximum Electrical Efficiency
    44.60%
View model

GCM34

GCM34 Electronic Power Generator Sets
  • Genset Rating Range
    6580 - 10300 kWe
  • Fuel Type
    Gas
  • Emission Level Up To
    Technische Anleitung (TA) Luft- 2002
View model

Mobile Generator Sets

The lifeblood of your business is reliable electric power. Mobile generator sets ensure that you’ll never be without it. Connect a unit to your building. Take one to a remote location. Connect multiple units in parallel.

XQE20

XQE20
  • Rating
    20 kVA (16 kW) Prime
  • Frequency
    50/60 Hz
  • Voltage
    220 - 415V
View model

XQE30

XQE30
  • Prime
    30 kVA (24 kW) Prime
  • Frequency
    50/60 Hz
  • Voltage
    220 - 415V
View model

XQ35

XQ35
  • Rating
    27 ekW (35 kVA) Prime
  • Frequency
    60 Hz
  • Voltage
    208 - 480V
View model

XQ60

XQ60 Tier 4 Final
  • Rating
    47.5 ekW (60 kVA) Prime
  • Frequency
    60 Hz
  • Voltage
    208 - 480 V
View model

XQE60

XQE60
  • Rating
    60 kVA (48 kW) Prime
  • Frequency
    50/60 Hz
  • Voltage
    220 - 415V
View model

XQP60

XQP60
  • Rating
    60 kVA Prime
  • Frequency
    50/60 Hz
  • Voltage
    127 - 480 V
View model

XQP100

XQP100
  • Rating
    100 kVA Prime
  • Frequency
    50/60 Hz
  • Voltage
    127 - 480 V
View model

XQ125

XQ125
  • Rating
    100 ekW (110 kVA) Prime
  • Frequency
    60 Hz
  • Voltage
    120 - 480 V
View model

XG135

XQ135
  • Rating
    135 ekW (170 kVA) Continuous
  • Frequency
    60Hz
  • Voltage
    208 - 480 V
View model

XQP150

XQP150
  • Rating
    150 kVA Prime
  • Frequency
    50/60 Hz
  • Voltage
    127 - 480 V
View model

XQP275

XQP275
  • Rating
    275 kVA Prime
  • Frequency
    50/60 Hz
  • Voltage
    127 - 480 V
View model

XQP300

XQP300
  • Rating
    300 kVA Prime
  • Frequency
    50/60 Hz
  • Voltage
    127 - 480 V
View model

XG400

XG400
  • Rating
    400 ekW (500 kVA) Continuous
  • Frequency
    60Hz
  • Voltage
    208 - 600 V
View model

XQ425

XQ375
  • Rating
    375 ekW (470 kVA) Standby
  • Frequency
    50/60 Hz
  • Voltage
    208 - 600 V
View model

XQP500

XQP500
  • Rating
    500 kVA Prime
  • Frequency
    50/60 Hz
  • Voltage
    127 - 480 V
View model

XQ570

XQ570
  • Rating
    455 ekW (568 kVA) Prime
  • Frequency
    60 Hz
  • Voltage
    208 - 600 V
View model

XQP1100

XQP1100
  • Rating
    1100 kVA Prime
  • Frequency
    50/60 Hz
  • Voltage
    127 - 480 V
View model

XQC1200

XQ1200
  • Rating
    1150kW (1438 kVA) Continuous
  • Frequency
    50/60 Hz
  • Voltage
    230 - 480 V
View model

XQ1475G

XQ1475G
  • Rating
    1475 ekW Continuous
  • Frequency
    50/60 Hz
  • Voltage
    230 - 480 V
View model

XQC1600

XQC1600
  • Rating
    1515 ekW (1893 kVA) Continuous
  • Frequency
    50/60 Hz
  • Voltage
    230 - 480 V
View model

XQ2000

XQ2000
  • Rating
    2000 ekW (2500 kVA) Standby
  • Frequency
    50/60 Hz
  • Voltage
    230 - 480 V
View model

XQ2000 - DGB

XQ2000 w/DGB
  • Rating
    1400 ekW (1750 kVA) Continuous
  • Rating
    1600 ekW (2000 kVA) Prime
  • Frequency
    50 Hz
View model

Switchgear and Paralleling Controls

Caterpillar offers switchgear suitable for applications ranging from single standby/load management to multi-unit utility paralleling installations.

Emergency Transfer Load Manager (EXL)

Emergency Transfer Load Manager
  • Configuration
    Wall mounted paralleling control system that monitors and controls a single generator and a single utility.
  • Modes of Operation
    Utility Import, Export, and base load operations, Peak shaving, and Emergency Standby. Closed Transition to/from Generator Power
  • Application
    LV and MV (208V-32kV)
View model

Cat EGP Switchgear

Cat EGP Switchgear
  • Configuration
    Traditional customizable PLC based floor standing switchgear capable of controlling and monitoring multiple utilities, generators, and loads
  • Modes of Operation
    Multi-unit Island and multi-unit standby mode with optional redundant controls and components.
  • Application
    LV and MV (208V - 38 kV)
View model

Cat XLM Switchgear

Cat XLM Switchgear
  • Configuration
    Traditional customizable PLC based floor standing switchgear capable of controlling and monitoring multiple utilities, generators, and loads
  • Modes of Operation
    Emergency Standby, Utility Import/Export, Peak shaving, and base load operations with redundant controls and components. Closed transition to/from generator power
  • Application
    LV and MV ( 208V - 38 kV
View model

Engine Generator Integrated Switchgear (EGIS)

Engine Generator Integrated Switchgear (EGIS)
  • Configuration
    Floor Standing modular switchgear paralleling system (Master Breaker Panel for the first 2 gensets, separate structures for up to 8 additional gensets , utility, and load control/distribution)
  • Modes of Operation
    Emergency Standby with redundant master control. Utility paralleling, peak shaving, and closed transition to/from Generator Power (with optional utility control panel)
  • Application
    LV only (208V - 480V)
View model

Engine Paralleling and Integration Control (EPIC)

Engine Paralleling and Integration Control (EPIC)
  • Configuration
    Remote modular paralleling control system (Master Control Panel for the first 2 gensets, separate add-on control panels for up 8 more gensets, and optional control panel for 1 utility breaker)
  • Modes of Operation
    Emergency Standby with redundant master control, Utility paralleling, peak shaving, and closed transition to/from Generator Power (with optional utility control panel)
  • Application
    LV and MV (208V-27kV)
View model

ATS ATC Breaker / Contactor

The ATC line of Automatic Transfer Switches are available in breaker or contactor based switches in sizes ranging from 30A through 5000A.

ATC Contactor Based Bypass Isolation Automatic Transfer Switch

ATS ATC Breaker / Contactor
  • Rating Range
    100 to 1200A
  • Transfer Type
    Bypass Isolation
  • Switch Type
    Contactor Based
View model

ATC Contactor-Based Automatic Transfer Switch

ATC Contactor-Based Automatic Transfer Switch
  • Rating Range
    40-1600A
  • Transfer Type
    Open / Closed Transition
  • Switch Type
    Contactor Based
View model

ATC Molded Case Circuit Breaker & Molded Case Switch ATS

ATC Molded Case Circuit Breaker & Molded Case Switch Automatic Transfer Switch
  • Rating Range
    30-1000A
  • Transfer Type
    Open transition
  • Switch Type
    Molded Case
View model

ATC Power Breaker & Case Switch Automatic Transfer Switch

ATC Power Breaker & Case Switch Automatic Transfer Switch
  • Rating Range
    200 to 5000A
  • Transfer Type
    Open Transition
  • Switch Type
    Power Breaker
View model

ATC Power Breaker Bypass Isolation Open/Closed Transition ATS

ATC Power Breaker Bypass Isolation Open/Closed Transition ATS
  • Rating Range
    200-5000A
  • Transfer Type
    Bypass isolation, Closed transition
  • Switch Type
    Power Breaker
View model

ATC Service Entrance Rated MCCB & Power Breaker Based ATS

ATC Service Entrance Rated MCCB
  • Rating Range
    30-5000A
  • Transfer Type
    Open / Closed / Delayed
  • Switch Type
    Molded Case and Power Breaker
View model

ATC-100 CONTROLLER

ATS ATC Breaker / Contactor
  • Rating Range
    120 to 480V, single phase and three phase @ 50/60 Hz
  • Transfer Type
    Switch application dependent
  • Switch Type
    Switch application dependent
View model

ATC-300+ CONTROLLER

ATC-300+ CONTROLLER
  • Rating Range
    120 to 600V, single phase and three phase @ 50/60 Hz
  • Transfer Type
    Switch application dependent
  • Switch Type
    Switch application dependent
View model

ATC-800 CONTROLLER

ATC-800 CONTROLLER
  • Rating Range
    120 to 600V, single phase and three phase @ 50/60 Hz
  • Transfer Type
    Switch application dependent
  • Switch Type
    Switch application dependent
View model

ATS MX Contactor

The MX line of Automatic Transfer Switches are contactor based switches in sizes ranging from 30A through 5000A.

CTE Series Automatic Transfer Switch

CTE Series Transfer Switch
  • Rating Range
    40-4000A
  • Transfer Type
    Open / Closed / 4 position switch
  • Switch Type
    Contactor Based
View model

CTS Series Automatic Transfer Switch

Systems  /  Power Systems  /  Electric Power Generation  /  ATS MX Contactor 	 CTS Series Automatic Transfer Switch
  • Rating Range
    40 to 4000A
  • Transfer Type
    Open transition
  • Switch Type
    Contactor Based
View model

CTSM and CTGM Series Manual Transfer Switches

CTSM and CTGM Series Manual Transfer Switches
  • Rating Range
    40-4000A
  • Transfer Type
    Open / Manual
  • Switch Type
    Contactor Based
View model

CTX Series Automatic Transfer Switch

ATS MX Contactor
  • Rating Range
    40-400A
  • Transfer Type
    Open transition
  • Switch Type
    Contactor Based
View model

MX150 Microprocessor Controller

MX150 Microprocessor Controller
  • Rating Range
    Switch Dependent
  • Transfer Type
    Application Dependent
  • Switch Type
    Application Dependent
View model

MX250 Microprocessor Controller

MX250 Microprocessor Controller
  • Rating Range
    Switch Dependent
  • Transfer Type
    Application Dependent
  • Switch Type
    Application Dependent
View model

Olympian Generator Sets

The range of Olympian™ generator sets provides reliable energy solutions for every business, every need. Olympian generators can be installed as the prime power source or standby service. They deliver dependable, clean, economical power – even in the most demanding conditions – and are available in a wide range of configurations with optional equipment.