Producing reliable power 500 kVA at 50 Hz, our DE500 GC generator set powerd by C13 diesel engine designed to ISO 8528-5 transient response requirements.
Cat
DE500 GC (50 Hz) Generator Set
Overview
Photos
360° View
Exterior
360° Exterior view. Double click on the image to zoom in on any area of the product.
Interior
360° Interior view. Double click on the image to zoom in on any area of the product.
Showroom
DE500 GC, Virtual Product Tour
Features
Specifications
-
Generator Set Specifications
Spec Value Maximum Rating 500 kVA Minimum Rating 500 kVA Emissions/Fuel Strategy Non Regulated Voltage 380 to 415 Volts Frequency 50 Hz Speed 1500 rpm Duty Cycle Standby -
Engine Specifications
Spec Value Engine Model C13 In-line 6, 4-cycle diesel Bore 5.1 in Stroke 6.2 in Displacement 763 in³ Compression Ratio 15.8:1 Aspiration Turbocharged Air-to-Air Aftercooled Fuel System EUI Governor Type Adem™A4 -
Generator Set Dimensions
Spec Value Length - Maximum 122 in Width - Maximum 52.7 in Height - Maximum 85.4 in Dry Weight - Genset (maximum) 6446 lb
Standard Equipment
Engine
- Cat® C13 Inline 6 cylinder, 4 stroke diesel
Control Panels
- GCCP 1.1
Governor
- Mechanical governor
Alternator
- A Frame standard alternator
Fuel Storage
- Single wall 8 hour fuel tank
Cooling System
- Radiator and cooling fan with guards
- Fan drive, battery charging alternator drive
Electrical Options
- 3 Pole Circuit breaker
- Neutral earth link
- 24 Volt battery with rack and cables
Air inlet system
- Air cleaner; light duty with disposable element
Lube system
- Lubricating oil
- Oil drain line with valve
Mounting system
- Captive linear vibration isolators
- Lifting provision and drag points
General
- Engine and alternator pre paint, Caterpillar yellow
Optional Equipment
Control panel
- Speed and Voltage adjust potentiometers
- PLG 4G/3G/Ethernet
- Annunciator
- Emergency E-Stop
Enclosure
- Cat GC enclosure
Electrical Options
- 4 Pole Circuit breaker
- Auxiliary contacts
- Padlockable circuit breaker
- Battery charger
- Wet battery
Alternator
- Space heater
- AVR
Fuel System
- Dual wall 8 hour fuel tank
- Single wall 8 hour fuel tank with spill containment
- Low fuel level shutdown
- Low and high fuel level alarms
Exhaust System
- Industrial silencer
- 10 dBA Attenuation silencer
Air inlet system
- Single stage air filter
- Dual element air filter
Certifications
- EU Certificate of Conformance (CE)
- EAC Certification
Extended service coverage
- 3, 4, 5 and 10 Years
Sign up for Ziegler CAT emails
Events, updates, and offers