Producing reliable power from 910 kVA to 1500 kVA at 50 Hz, our C32 diesel generator sets are made to meet your mission critical, continuous, standby and prime applications. We’ve designed each to ISO 8528-5 transient response requirements and to accept 100 percent rated load in one step. Our C32 generator sets are made for demands, so you can make yours.
Cat
C32 | 1250 kVA 50 Hz Generator Set
Overview
Photos
Videos
360° View
Exterior
360° Exterior view. Double click on the image to zoom in on any area of the product.
Showroom
C32 (50), Virtual Product Tour
Features
Specifications
-
Generator Set Specifications
Spec Value Maximum Rating 1500 kVA Minimum Rating 910 kVA Emissions/Fuel Strategy Low Fuel, Low Emissions Voltage 400 to 3300 Volts Frequency 50 Hz Speed 1500 rpm Duty Cycle Standby, Mission Critical, Prime, Continuous -
Engine Specifications
Spec Value Engine Model C32 TA, V-12, 4-Stroke Water-Cooled Diesel Bore 5.71 in Stroke 6.38 in Displacement 1958.86 in³ Compression Ratio 15.0:1 Aspiration Turbocharged, Air to Air Aftercooled Fuel System MEUI Governor Type Adem™A4 -
Generator Set Dimensions
Spec Value Length - Minimum 164 in Length - Maximum 176.6 in Width - Minimum 66.3 in Width - Maximum 87.8 in Height - Minimum 85.1 in Height - Maximum 86.4 in Dry Weight - Genset (minimum) 14700 lb Dry Weight - Genset (maximum) 17855 lb
Standard Equipment
Air Inlet System
- Single element canister type with service indicator
Control Panel
- GCCP Control panel
- Control features
- Programmable protective relaying functions
- Digital indicators
- Warning shutdowns
- Communications
Cooling System
- Fan and belt guards
- Radiator fan and fan drive
- ATAAC
- Coolant drain line with valve
- Caterpillar extended life coolant
- Low coolant level sensor
Exhaust
- Exhaust manifold - dry
- 203 mm (8 in) ID round flanged outlet
Fuel System
- Primary fuel filter with water separator
- Fuel priming pump
- Secondary fuel filters
- Fuel cooler
Generators and Attachments
- Integrated voltage regulator (IVR)
- Permanent magnet excitation (PMG)
- 3 Phase brushless
- Reactive droop
- Internal excitation (IE)
- NEMA Class H insulation
- Class H temperature rise at 40C ambient
- Salient pole
- Winding temperature detectors
- 6 Lead
- IEC standard hole pattern
- Busbar connections, top center mounted, top cable entry
Governing System
- ADEM(tm) A4
Mounting System
- Rails - engine/generator/radiator mounting
- Rubber anti-vibration mounts
Lube System
- Oil drain lines and valve
- Integral lube Oil cooler
- Fumes disposal
- Lubricating oil
- Oil filter, filler and dipstick
- Gear type lube oil pump
Power Termination
- Busbar
Starting / Charging System
- 24 Volt electric starting motor
- Battery, rack and cables
- Battery disconnect switch
- 45 Amp Charging alternator
General
- Caterpillar yellow with high gloss black rails & radiator
- RH service
- Flywheel and flywheel housing-SAE
- SAE standard rotation
Optional Equipment
Air Inlet System
- Dual element air cleaner
- Heavy duty air cleaner
- Standard air cleaners
Circuit breakers
- 1600, 2000, 2500 and 3200 Amp, 3 Pole, IEC-Rated Circuit breakers
- Enclosures - Control packaging
- Cable supports
- Center posts busbars
- Circuit breaker wiring groups
- Power connection covers
- Shrouds
- 400, 800, 1200, 1600, 2000, 2500 and 3000 Amp, 3 Pole, UL-100% Rated Circuit breakers
- 800, 1600, 2000, 2500 and 3200 Amp, 4 Pole, IEC rated Circuit breakers
Control Panels
- GCCP Control panel
Cooling System
- Radiator duct flange
- Certified radiator
- High ambient radiator
- Standard radiator
- Extended life coolant
Enclosures
- Enclosure fuel tank options
- Sound attenuated enclosure
- Enclosure louvres - fixed and motorized
- Color options
- AC Panel, outlets and lights
- Premium sound attenuated enclosure
- Cold weather bundle
- Panel bracket
- DC lighting package
Exhaust System
- Exhaust through the wall kit
- Flange and exhaust expanders
- Flanges
- Guard and shield system
- All C32 engines have 203 mm (8 in) exhaust outlets
- Elbow mounting kit
- Mufflers
- Flexible fittings
Generator and Attachments
- Low voltage generators
- Medium voltage generators
Lube System
- Oil pan
- Prelube manual sump pump
- Oil level regulator
Mounting System
- IBC vibration isolators
- Mounting base types
- Spring type vibration isolators
- Standard package isolators
Power Termination
- Circuit breakers, IEC compliant
- Circuit breakers, UL listed
Power Connections
- Low voltage connection cables
- Neutral grounding connection
- Center post busbars
Starting / Charging System
- 10 Amp enclosure Battery charger
- Space heater
- 10 Amp Battery charger
- 20 Amp Battery charger
- 35 Amp Battery charger
- Electric starting motor - Standard/heavy duty
- Standard 24 volt open package battery set - Dry
- Jacket water heater
Special Tests / Reports
- PGS Test report @ 1.0 power factor
- Standard engine test
- Generator test report
- Custom generator TVA report
- PGS Test report @ 0.8 power factor
- CSA test and certification
- IBC seismic Certifications
- Standard genset Torsional Vibration Analysis (TVA) report
- OSHPD seismic Certifications
General
- Special paint
- US aid emblem
Sign up for Ziegler CAT emails