The DE400 GC diesel generator sets have been developed for your standby applications. Producing reliable power of 400 kVA at 50 Hz, our C9.3 diesel-powered DE400 GC generator set is designed to ISO 8528-5 transient response requirements
Cat
DE400 GC Generator Set
Overview
Photos
360° View
Exterior
Open Set
Showroom
DE400 GC, Virtual Product Tour
Features
Specifications
-
Generator Set Specifications
Spec Value Maximum Rating 400 kVA Minimum Rating 400 kVA Emissions/Fuel Strategy Non-Certified Emissions Voltage 380 to 415 Volts Frequency 50 Hz Speed 1500 rpm Duty Cycle Standby -
Engine Specifications
Spec Value Engine Model C9.3B, I-6, 4-cycle diesel Bore 4.53 in Stroke 5.87 in Displacement 567.5 in³ Compression Ratio 16.5:1 Aspiration Turbocharged Air-to-Air Aftercooled Fuel System Common Rail Governor Type ADEM™A6 -
Generator Set Dimensions
Spec Value Length - Maximum 104.8 in Width - Maximum 44 in Height - Maximum 69.5 in Dry Weight - Genset (maximum) 5070.6 lb
Standard Equipment
Engine
- C9.3B, Inline 6 cylinder, 4 stroke diesel
Air, Cooling & Exhaust
- Standard air filter
Genset Control
- GCCP 1.1
Governor
- Adem A4
Alternator
- A Frame standard alternator
Fuel Storage
- Single wall 8 hour fuel tank
General
- Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment
Air, Cooling & Exhaust
- 6" Elbow kit
- Dual element air filter
- 5-6" Exhaust adapter
- Canopy silencer
- 5" Elbow kit
- 6" Elbow kit
- 6" Muffler - 25 dBA attenuation
- 5" Muffler - 10 dBA Attenuation
- Single stage air filter
- No muffler
Alternator Requirements
- IP Standard @ 21 FUW A-Frame
- Space heater
Auxiliary Supply Voltage
- 240V
Certification
- Australia, CIS, Gulf Certification
- Certificate of Conformance 13
Circuit breaker
- 3 Pole Circuit breaker 800A
- Circuit breaker padlock
- 4 Pole Circuit breaker 630A
- 4 Pole Circuit breaker 1250A
- 3 Pole Circuit breaker 630A
- 4 Pole Circuit breaker 800A
- Overload via alarm switch on breaker
- Neutral earth link
- 3 Pole Circuit breaker 1250A
- Auxiliary contacts
- Shunt Trip
Enclosure
- Cat GC enclosure
Fuel Storage
- Low fuel level shutdown
- Fuel level alarms
- Low fuel level alarm
- Single wall tank with containment 01
- High fuel level alarm
- Dual wall 8 hour fuel tank
Genset Control
- PLG Cellular 4G E
- Oil temperature displays
- Coolant heater
- Battery charger
- Standby Pack (Smart Jacket water heater, Battery charger)
- PLG Cellular 4G U
- Voltage adjust potentiometer
- Low coolant temperature alarm
- Speed adjust potentiometer
- PLG Ethernet