Ag Agriculture Blog IconBehind the Scenes Blog IconConstruction Blog IconEquipment Maintenance Blog Icon Power Systems Blog Icon Thumbs Down Thumbs Up! Small Business Blog IconTachnology Blog Icon Constructioncontrol-smallcost-smallefficiency-smallflexibility-smallHoursHours Location HoursMapMapMenu AgMenu AttachmentsMenu BlogMenu CareersMenu ChecklistMenu ConstructionMenu MaintenanceMenu NewMenu PowerMenu RebuildsMenu RentMenu ServiceMenu TechnologyMenu TestimonialsMenu Training Menu Truck Menu UsedNewArtboard 1Parts Phone Phone PhonePower Systemsproductivity-smallRentalRepSafetyServiceSpecialsTechtestimonial-iconToolsTrainingTruckUsed

Cat

DE165 GC Generator Set (50 Hz)

Maximum Rating

163.9 kVA

Minimum Rating

163.9 kVA

Emissions/Fuel Strategy

Non Regulated

Overview

Producing reliable power of 165 kVA at 50 Hz, our DE165 GC diesel generator set is designed to meet ISO 8528-5 transient response requirements.

Photos

360° View

Exterior

360° Exterior view. Double click on the image to zoom in on any area of the product.

Showroom

DE165 GC, Virtual Product Tour

Features

Specifications

  • Generator Set Specifications
    Spec Value
    Maximum Rating 163.9 kVA
    Minimum Rating 163.9 kVA
    Emissions/Fuel Strategy Non Regulated
    Voltage 380 to 415 Volts
    Frequency 50 Hz
    Speed 1500 rpm
    Duty Cycle Standby
  • Engine Specifications
    Spec Value
    Engine Model C7.1 I-6, 4-Cycle Diesel
    Bore 4.1 in
    Stroke 5.3 in
    Displacement 427.8 in³
    Compression Ratio 16.0:1
    Aspiration Turbocharged Air To Air Charge Cooled
    Fuel System Inline
    Governor Type Mechanical
  • Generator Set Dimensions
    Spec Value
    Length - Maximum 130.9 in
    Width - Maximum 44.6 in
    Height - Maximum 65.6 in
    Dry Weight - Genset (maximum) 1834 lb

Standard Equipment

Engine

  • C7.1, Inline 6 cylinder, 4 stroke diesel

Control Panels

  • GCCP 1.1

Alternator

  • A Frame standard alternator

Fuel Storage

  • Single wall 8 hour fuel tank

Governor

  • Mechanical governor

Enclosure

  • Cat GC enclosure

Air, Cooling & Exhaust

  • Enclosure silencer

General

  • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

Auxiliary Supply Voltage

  • 120V

Certification

  • Certificate of Conformance
  • Australia, CIS, Gulf Certification

Fuel Storage

  • Dual wall 8 hour fuel tank
  • High fuel level alarm
  • Single wall tank with containment
  • Low fuel level shutdown
  • Low fuel level alarm

Alternator Requirements

  • Space heater

Genset Control

  • Volt free contacts for common alarm
  • Volt free contacts for genset running
  • Battery charger
  • Panel mounted audible alarm
  • Earth leakage
  • USB to RS485 Communications device
  • Earth fault
  • Emergency stop with key
  • Coolant heater
  • Battery
  • Standby Pack (Smart Jacket water heater, Battery charger)
  • Low coolant level shutdown

Circuit breaker

  • 4 Pole Circuit breaker 200A
  • 3 Pole Circuit breaker 630A
  • 4 Pole Circuit breaker 250A
  • 3 Pole Circuit breaker 200A
  • 3 Pole Circuit breaker 250A
  • 4 Pole Circuit breaker 630A
  • 4 Pole Circuit breaker 400A
  • Circuit breaker padlock
  • Neutral earth link
  • Overload via alarm switch on breaker
  • 3 Pole Circuit breaker 400A

Testing & Packaging

  • PGS Test report @ 1.0 power factor
  • PGS Test report @ 0.8PF