Skip to main content Skip to navigation
Ag Agriculture Blog IconBehind the Scenes Blog IconConstruction Blog IconEquipment Maintenance Blog Icon Power Systems Blog Icon Thumbs Down Thumbs Up! Small Business Blog IconTachnology Blog Icon Constructioncontrol-smallcost-smallefficiency-smallflexibility-smallHoursHours Location HoursMapMapMenu AgMenu AttachmentsMenu BlogMenu CareersMenu ChecklistMenu ConstructionMenu MaintenanceMenu NewMenu PowerMenu RebuildsMenu RentMenu ServiceMenu TechnologyMenu TestimonialsMenu Training Menu Truck Menu UsedNewArtboard 1Parts Phone Phone PhonePower Systemsproductivity-smallRentalRepSafetyServiceSpecialsTechtestimonial-iconToolsTrainingTruckUsed

Cat

DE50 GC Generator Set (60 Hz)

Maximum Rating

45 ekW

Duty Cycle

Standby

Emissions/Fuel Strategy

Non Regulated

Overview

Producing reliable power of 45 ekW at 60 Hz, our DE50 GC diesel generator set is designed to meet ISO 8528-5 transient response requirements.

Photos

360° View

Exterior

Showroom

DE50 GC, Virtual Product Tour

Features

Specifications

  • Generator Set Specifications
    Spec Value
    Maximum Rating 45 ekW
    Duty Cycle Standby
    Emissions/Fuel Strategy Non Regulated
    Voltage 220 to 480 Volts
    Frequency 60 Hz
    Speed 1800 rpm
    Minimum Rating 45 ekW
  • Engine Specifications
    Spec Value
    Engine Model Cat® C3.3, In-line 3, 4-cycle diesel
    Bore 4.1 in
    Stroke 5 in
    Displacement 201.4 in³
    Compression Ratio 17.25:1
    Aspiration Turbocharged
    Fuel System Inline
    Governor Type Mechanical
  • Generator Set Dimensions
    Spec Value
    Length - Maximum 89.7 in
    Width - Maximum 35.4 in
    Height - Maximum 52 in
    Dry Weight - Genset (maximum) 1031 lb

Standard Equipment

Engine

  • C3.3, Inline 3 cylinder, 4 stroke diesel

Genset Control

  • GCCP 1.1

Governor

  • Mechanical governor

Alternator

  • A Frame standard alternator

Fuel Storage

  • Single wall 8 hour fuel tank

Enclosure

  • Cat GC enclosure

Air, Cooling & Exhaust

  • Enclosure silencer

General

  • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

Certification

  • Certificate of Conformance
  • Australia, CIS, Gulf Certification

Auxiliary Supply Voltage

  • 120V

Alternator Requirements

  • Space heater

Fuel Storage

  • Dual wall 8 hour fuel tank
  • Single wall tank with containment
  • Low fuel level shutdown
  • Low fuel level alarm
  • High fuel level alarm

Genset Control

  • Battery charger
  • Volt free contacts for common alarm
  • Volt free contacts for genset running
  • Earth leakage
  • Earth fault
  • USB to RS485 Communications device
  • Emergency stop with key
  • Panel mounted audible alarm
  • Coolant heater
  • Standby Pack (Smart Jacket water heater, Battery charger)
  • Battery
  • Low coolant level shutdown

Circuit breaker

  • 3 Pole Circuit breaker 63A
  • 3 Pole Circuit breaker 80A
  • 3 Pole Circuit breaker 100A
  • 3 Pole Circuit breaker 125A
  • 3 Pole Circuit breaker 160A
  • 3 Pole Circuit breaker 200A
  • 4 Pole Circuit breaker 63A
  • 4 Pole Circuit breaker 80A
  • 4 Pole Circuit breaker 100A
  • 4 Pole Circuit breaker 125A
  • 4 Pole Circuit breaker 160A
  • 4 Pole Circuit breaker 200A
  • Circuit breaker padlock
  • Neutral earth link
  • Overload via alarm switch on breaker

Testing & Packaging

  • PGS Test report @ 1.0 power factor
  • PGS Test report @ 0.8PF