Skip to main content Skip to navigation
Ag Agriculture Blog IconBehind the Scenes Blog IconConstruction Blog IconEquipment Maintenance Blog Icon Power Systems Blog Icon Thumbs Down Thumbs Up! Small Business Blog IconTachnology Blog Icon Constructioncontrol-smallcost-smallefficiency-smallflexibility-smallHoursHours Location HoursMapMapMenu AgMenu AttachmentsMenu BlogMenu CareersMenu ChecklistMenu ConstructionMenu MaintenanceMenu NewMenu PowerMenu RebuildsMenu RentMenu ServiceMenu TechnologyMenu TestimonialsMenu Training Menu Truck Menu UsedNewArtboard 1Parts Phone Phone PhonePower Systemsproductivity-smallRentalRepSafetyServiceSpecialsTechtestimonial-iconToolsTrainingTruckUsed

Cat

DE55 GC Generator Set (50 Hz)

Maximum Rating

55.0 kVA

Minimum Rating

55.0 kVA

Emissions/Fuel Strategy

Non Regulated

Overview

Producing 55 kVA of reliable power at 50 Hz, our DE55 GC diesel generator set is designed to meet ISO 8528-5 transient response requirements.

Photos

360° View

Exterior

Showroom

DE55 GC, Virtual Product Tour

Features

Specifications

  • Generator Set Specifications
    Spec Value
    Maximum Rating 55.0 kVA
    Minimum Rating 55.0 kVA
    Emissions/Fuel Strategy Non Regulated
    Voltage 380 to 415 Volts
    Frequency 50 Hz
    Speed 1500 rpm
    Duty Cycle Standby
  • Engine Specifications
    Spec Value
    Engine Model Cat® C3.3, In-line 3, 4-cycle diesel
    Bore 4.1 in
    Stroke 5 in
    Displacement 201.4 in³
    Compression Ratio 17.25:1
    Aspiration Turbocharged
    Fuel System Inline
    Governor Type Mechanical
  • Generator Set Dimensions
    Spec Value
    Length - Maximum 76.6 in
    Width - Maximum 34.3 in
    Height - Maximum 48.7 in
    Dry Weight - Genset (maximum) 2114 lb

Standard Equipment

Engine

  • C3.3, Inline 3 cylinder, 4 stroke diesel

Genset Control

  • GCCP 1.1

Governor

  • Mechanical governor

Alternator

  • A Frame standard alternator

Fuel Storage

  • Single wall 8 hour fuel tank

Enclosure

  • Cat GC enclosure

Air, Cooling & Exhaust

  • Enclosure silencer

General

  • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

Certification

  • Australia, CIS, Gulf Certification
  • Certificate of Conformance

Alternator Requirements

  • Space heater

Auxiliary Supply Voltage

  • 120V

Fuel Storage

  • Dual wall 8 hour fuel tank
  • Single wall tank with containment
  • Low fuel level alarm
  • Low fuel level shutdown
  • High fuel level alarm

Genset Control

  • Battery charger
  • Volt free contacts for genset running
  • Volt free contacts for common alarm
  • Earth fault
  • Panel mounted audible alarm
  • Earth leakage
  • USB to RS485 Communications device
  • Emergency stop with key
  • Low coolant level shutdown
  • Standby Pack (Smart Jacket water heater, Battery charger)
  • Battery
  • Coolant heater

Circuit breaker

  • 3 Pole Circuit breaker 63A
  • 3 Pole Circuit breaker 80A
  • 3 Pole Circuit breaker 100A
  • 3 Pole Circuit breaker 125A
  • 3 Pole Circuit breaker 160A
  • 3 Pole Circuit breaker 200A
  • 4 Pole Circuit breaker 80A
  • 4 Pole Circuit breaker 63A
  • 4 Pole Circuit breaker 100A
  • 4 Pole Circuit breaker 125A
  • 4 Pole Circuit breaker 160A
  • 4 Pole Circuit breaker 200A
  • Circuit breaker padlock
  • Neutral earth link
  • Overload via alarm switch on breaker

Testing & Packaging

  • PGS Test report @ 1.0 power factor
  • PGS Test report @ 0.8 power factor