Producing reliable power of 100 ekW at 60 Hz, our D100 GC diesel generator sets designed to ISO 8528-5 transient response requirements. All D100 GC generator sets meet EPA Stationary Emergency (Tier 3) emissions standards.
Cat
D100 GC Generator Set
Overview
Photos
360° View
Exterior
360° Exterior view. Double click on the image to zoom in on any area of the product.
Interior
360° Interior view. Double click on the image to zoom in on any area of the product.
Showroom
D100 GC, Virtual Product Tour
Features
Specifications
-
Generator Set Specifications
Spec Value Maximum Rating 100 ekW Minimum Rating 100 ekW Emissions/Fuel Strategy U.S. EPA Cert., Tier 3 Voltage 208 to 600 Volts Frequency 60 Hz Speed 1800 rpm Duty Cycle Standby -
Engine Specifications
Spec Value Engine Model C4.4, In-line 4, 4-cycle diesel Bore 4.1 in Stroke 5 in Displacement 269 in³ Compression Ratio 16.7:1 Aspiration Turbocharged Fuel System Common Rail Governor Type Mechanical, ADEM™A4 -
Generator Set Dimensions
Spec Value Length - Maximum 82.6 in Width - Maximum 43.3 in Height - Maximum 52.9 in Dry Weight - Genset (maximum) 2222 lb
Standard Equipment
Air Inlet System
- Air cleaner; light duty with disposable element
- Air cleaner
Cooling System
- Coolant drain line with valve
- Radiator and cooling fan with guards
- Caterpillar extended life coolant
- Fan drive, battery charging alternator drive
Control Panel
- GCCP 1.2 Control panel
Exhaust System
- Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
Fuel System
- Standard open set fuel tank/base supplied base, formed steel with single wall integral 24-hour fuel tank
Generator
- Circuit breaker, IEC, 3 pole, mounted in tower panel
- IP23 Protection
- Tower panel, IP22, bottom cable entry
- 12 Leads
- Voltage regulator (single phase sensing)
- Segregated low voltage (AC/DC) wiring panel
Governing System
- Mechanical and electrical governing system - model dependent
Lube System
- Lubricating oil
- Oil drain line with valve
Mounting System
- Termination points for coolant and lube oil drain lines
- Captive linear vibration isolators between base and engine-generator
- Includes lifting provision and drag points
Starting/Charging System
- Batteries
- 24V battery with rack and cables
General
- Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment
Alternator System
- Anti-condensation heater
- 3 phase sensing
- Permanent magnet excitation (PMG)
- R Frame auxilliary winding
- Quadrature droop kit
Circuit breakers
- Circuit breaker upgrades - 4 Pole circuit reaker to 250A, 400A and 630 A
Cooling System
- Coolant heater
- Low coolant temperature alarm
- Low coolant level shutdown
Control Panel Options
- Earth fault (2 wire only)
- Control panel heater
- GCCP 1.2 Control panel
- Volt free contacts
- Emergency stop with key
- Voltage adjust potentiometer
- Overload shutdown via breaker
- Panel mounted audible alarm
- Battery charger
- Earth leakage (2 wire only)
- Speed adjust potentiometer
Enclosures
- Sound attenuated Level 2 enclosure
Fuel System
- Low fuel level alarm
- Bunded fuel tank
- Low fuel level shutdown
- High fuel level alarm
Mounting Options
- Battery removal
- Electronic governor
- Industrial silencer
- External single point lift - enclosure
- Silencer installation kit
Special Packing/Inspectons for Shipment
- PGS Test report @ 0.8 power factor
- PGS Test report @ 1.0 power factor
General - Accessories / Miscellaneous
- Packing case - canopied set
- Packing case - compact set
- Stone guards/rad trans flange
Sign up for Ziegler CAT emails
Events, updates, and offers