Producing reliable power from 24.0 to 65.0 kVA at 50 Hz, our C3.3 diesel generator sets designed to ISO 8528-5 transient response requirements. All C3.3 generator sets are R96/EUIIIa equivalent emissions compliant.
Cat
C3.3 Generator Set
Overview
Photos
360° View
Exterior
Enclosure
Documents
- Electric Power Ratings Guide
- 24-220 KVA SA LVL 2 Enclosure
- DE33E0, 50 Hz 33.0 kVA, M Frame, Low BSFC Emissions Compliant Spec Sheet
- DE33E3, 50 Hz 33.0 kVA, M Frame, Low EUIIIA Emissions Compliant Spec Sheet
- DE40E0S, 50 Hz 40.0 kVA, M Frame, Low BSFC Emissions Compliant Spec Sheet
- DE50E2, 50 Hz 50.0 kVA, M Frame, EUII Emissions Compliant Spec Sheet
- DE65E0, 50 Hz 55.0 kVA, M Frame, Low BSFC Emissions Compliant Spec Sheet
- DE55E0, 50 Hz 55.0 kVA, M Frame, Low BSFC Emissions Compliant Spec Sheet
- DE26E0S, 50 Hz 26.0 kVA, M Frame, Low BSFC Emissions Compliant Spec Sheet
- DE26E3S, 50 Hz 26.0 kVA, M Frame, EUIIIA Emissions Compliant Spec Sheet
- DE40E2S, 50 Hz 40.0 kVA, M Frame, EUII Emissions Compliant Spec Sheet
- DE50E0S, 50 Hz 50.0 kVA, M Frame, Low BSFC Emissions Compliant Spec Sheet
- DE33E0, 50 Hz 33.0 kVA, 60 Hz 37.5 LC Frame, Low BSFC Emissions Compliant Spec Sheet
- DE33E3, 50 Hz 33.0 kVA, LC Frame, EUIII Emissions Compliant Spec Sheet
- DE50E0, 50 Hz 50.0 kVA, 60 Hz 56.3 LC Frame, Low BSFC Emissions Compliant Spec Sheet
- DE50E2, 50 Hz 55.0 kVA, LC Frame, EU II Emissions Compliant Spec Sheet
- DE65E0, 50 Hz 65.0 kVA, 60 Hz 75.0 LC Frame, Low BSFC Emissions Compliant Spec Sheet
- DE55E0, 50 Hz 55.0 kVA, 60 Hz 62.5 LC Frame, Low BSFC Emissions Compliant Spec Sheet
Features
Specifications
-
Generator Set Specifications
Spec Value Maximum Rating 65.0 kVA Minimum Rating 24.0 kVA Emissions/Fuel Strategy EU Stage II R96/EUIIIa Voltage 110 to 480 Volts Frequency 50 Hz Speed 1500 rpm Duty Cycle Standby, Prime -
Engine Specifications
Spec Value Engine Model Cat® C3.3 Bore 4.1 in Stroke 5 in Displacement 201.4 in³ Compression Ratio 17.25:1, 19.25:1 Aspiration Turbocharged Fuel System Direct Injection Governor Type Mechanical -
Generator Set Dimensions
Spec Value Length - Maximum 43.9 in Width - Maximum 38.2 in Height - Maximum 53.6 in
Standard Equipment
Air Inlet System
- Air cleaner; light duty with disposable element
Control Panel
- GCCP 1.3
Cooling System
- Coolant drain line with valve
- Radiator and cooling fan with guards
- Caterpillar extended life coolant
- Fan drive, battery charging alternator drive
Exhaust System
- Stub pipe, gaskets, raincap & SAE exhaust flange for customer use - shipped loose
Fuel System
- Standard open set fuel tank/base supplied
- Base, formed steel with single wall integral 8-hour fuel tank
Generators and Generator Attachments
- Voltage regulator (single phase sensing)
- Tower panel, IP22, bottom cable entry
- Circuit breaker, IEC, 3 pole, mounted in tower panel
- IP23 Protection
- Segregated low voltage (AC/DC) wiring panel
Governing System
- Mechanical and electrical governing system - model dependant
Generators and attachments
- 12 Leads
Lube System
- Lubricating oil
- Oil drain line with valve
Mounting System
- Captive linear vibration isolators between base and engine-generator
- Termination points for coolant and lube oil drain lines
- Includes lifting provision and drag points
Starting / Charging System
- 12V Battery with rack & cables
General
- Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment
Alternator System
- R Frame auxilliary winding
- Anti-condensation heater
- LC Frame alternator with coastal protection
- LC Frame alternator
- Permanent magnet excitation (PMG)
Circuit breakers
- Padlockable breaker device
- 4 Pole Circuit breaker to 250A
Control Panels
- GCCP 1.3
Control Panel Options
- Emergency stop with key
Cooling System
- Low coolant level shutdown
- Coolant heater
- Low coolant temperature alarm
Certifications
- Global Certification for CIS
- European upgrade to STD set for "CE"
Enclosures
- Sound attenuated level 1 enclosure (GALV)
- CEE for sockets for enclosure
- Sound attenuated level 2 enclosure CE
- Rental pack (CAE only)
- Socket blanking plate
Fuel System
- High fuel level alarm
- Open set narrow tankbase
- Compact skidbase for open sets
- Low fuel level shutdown
- Low fuel level alarm
- Skidbase for CALG enclosure sets
- Bunded fuel tank
Mounting Options
- Battery removal
- Residential silencer
- Silencer installation kit
- External single point lift - enclosure
- Electronic governor
Special Packing Inspections
- PGS Test report @ 0.8 power factor
- PGS Test report @ 1.0 power factor
General
- Packing case - compact set
- Packing case - canopied set
Sign up for Ziegler CAT emails
Events, updates, and offers