Producing reliable power from 6.8 to 9.5 kVA at 50 Hz, our C1.1 diesel generator sets designed to ISO 8528-5 transient response requirements. All C1.1 generator sets are R96/EUIIIa equivalent emissions compliant.
Cat
C1.1 Generator Set
Overview
Photos
360° View
Exterior
Enclosure
Documents
- Electric Power Ratings Guide
- DE7.5E3S 50 Hz 7.5 kVA, 60 Hz 8.8 kVA, M Frame, EU IIIA Compliant Emissions Spec Sheet
- DE9.5E3 50 Hz 9.5 kVA, 60 Hz 11.0 kVA, M Frame, EU IIIA Emissions Compliant Spec Sheet
- DE9.5E3 50 Hz 9.5.0 kVA, 60 Hz 11.0 kVA, M Frame, EU IIIA (EUR-1) Compliant Emissions Spec Sheet
- DE7.5E3S 50 Hz 7.5 kVA, 60 Hz 8.8 kVA, LC Frame, EU IIIA Emissions Compliant Spec Sheet
- DE9.5E3 50 Hz 9.5 kVA, 60 Hz 11.0 kVA, LC Frame, EU IIIA Emissions Compliant Spec Sheet
- DE9.5E3 50 Hz 9.5 kVA, 60 Hz 11.0 kVA, LC Frame, EU IIIA (EUR-1) Emissions Compliant Spec Sheet
- C1C2 Diesel Generator Sets, 6.8 - 22 kVA, 50/60 Hz, Spec Sheet
- C1C2 Diesel Generator Sets, 6.8 - 22 kVA, 50/60 Hz, Spec Sheet
Features
Specifications
-
Generator Set Specifications
Spec Value Maximum Rating 9.5 kVA Minimum Rating 6.8 kVA Emissions/Fuel Strategy R96/EUIIIa Equivalent Voltage 110 to 415 Volts Frequency 50 Hz Speed 1500 rpm Duty Cycle Standby, Prime -
Engine Specifications
Spec Value Engine Model C1.1, In-line 4 4-cycle diesel Bore 3 in Stroke 3.2 in Displacement 69 in³ Compression Ratio 23.0:1 Aspiration Naturally Aspirated Fuel System Indirect Injection Governor Type Mechanical -
Generator Set Dimensions
Spec Value Length - Maximum 55.1 in Width - Maximum 24.4 in Height - Maximum 39.2 in
Standard Equipment
Air Inlet System
- Air cleaner; light duty with disposable element
Control Panel
- GCCP1.3 Control panel
Cooling System
- Caterpillar extended life coolant
- Coolant drain line with valve
- Fan drive, battery charging alternator drive
- Radiator and cooling fan with guards
Exhaust System
- Stub pipe, gaskets, raincap & SAE exhaust flange for customer use - shipped loose
Fuel System
- Base, formed steel with single wall integral 8-hour fuel tank
- Standard open set fuel tank/base supplied
General
- Engine and alternator pre-paint, Caterpillar yellow
Generators and Generator Attachments
- 12 Leads
- Circuit breaker, IEC, 3 pole, mounted in tower panel
- IP23 Protection
- Segregated low voltage (AC/DC) wiring panel
- Tower panel, IP22, bottom cable entry
- Voltage regulator (single phase sensing)
Governing System
- Mechanical governing system
Lube System
- Lubricating oil
- Oil drain line with valve
Mounting System
- Anti-vibration mounts
- Captive linear vibration isolators between base and engine-generator
- Includes lifting provisions and termination points for coolant
- Skidbase as standard
Starting / Charging System
- 12 Volt battery with rack and cables
Optional Equipment
Alternator Options
- Coastal insulation protection
Certificates
- European upgrade to STD set for CE certificate
- Global certification for CIS
Circuit breakers
- 4 Pole Circuit breaker
- Padlockable breaker device
Control Panel
- Battery charger
- Emergency stop with key
Cooling System
- Coolant heater
Enclosures
- Single point lift for enclosure
- Sound attenuated enclosure (GALV)
Fuel System
- Low fuel level alarm
General
- Packing case - canopied set
- Packing case - compact set
- Radiator stone guard
Mounting Options
- Battery removal
- Industrial silencer removal
- Silencer installation kit
Special Test and Inspection
- PGS Test report @ 1.0 power factor
Sign up for Ziegler CAT emails
Events, updates, and offers