Skip to main content Skip to navigation
Ag Agriculture Blog IconBehind the Scenes Blog IconConstruction Blog IconEquipment Maintenance Blog Icon Power Systems Blog Icon Thumbs Down Thumbs Up! Small Business Blog IconTachnology Blog Icon Constructioncontrol-smallcost-smallefficiency-smallflexibility-smallHoursHours Location HoursMapMapMenu AgMenu AttachmentsMenu BlogMenu CareersMenu ChecklistMenu ConstructionMenu MaintenanceMenu NewMenu PowerMenu RebuildsMenu RentMenu ServiceMenu TechnologyMenu TestimonialsMenu Training Menu Truck Menu UsedNewArtboard 1Parts Phone Phone PhonePower Systemsproductivity-smallRentalRepSafetyServiceSpecialsTechtestimonial-iconToolsTrainingTruckUsed

Caterpillar

C9.3 Marine Generator Set

C9.3 Marine Generator Set

Photos

Features

Specifications

  • Generator Set Specifications
    Spec Value
    Speed 200 ekW - 274 ekW
    Emissions/Fuel Strategy IMO II, IMO III, U.S. EPA Tier 3, China Stage II
  • Engine Specifications
    Spec Value
    Aspiration Turbocharged-aftercooled
    Bore 4.5 in
    Stroke 5.8 in
    Rated Engine Speed 1,500, 1,800 rpm
    Cooling Heat exchanger and separate or combined keel cooled options
    Displacement 567.5 in
    Oil Change Interval 500 hrs
    Configuration Inline 6, 4-Stroke Cycle diesel
    Refill Capacity Lube Oil System w/oil filter change: 24.5 L (6.5 gal)
    Governor Electronic
    Rotation from Flywheel End Counterclockwise
  • Generator Set Dimensions
    Spec Value
    Width 38.5 in / 978 mm
    Length 57.2 in / 1,452 mm
    Engine Dry Weight 2083 - 2474 lb / 945 - 1122 kg
    Height 43.0 in / 1,093 mm

Standard Equipment

Standard Equipment

  • Water-cooled turbocharger and exhaust manifold
  • Electronic control system
  • Thermostats and housing
  • Gear-driven Sea water pump (self-priming)
  • Common rail fuel system
  • Shell and tube jacket water heat exchanger
  • Corrosion-resistant Sea water aftercooler
  • Engine oil cooler
  • Vibration damper and guard
  • Primary fuel filters

Optional Equipment

Optional Attachments

  • Alternators - 24V 70 or 105 amp, 12V 110 amp
  • Closed crankcase ventilation
  • Transmission gear oil cooler (engine mounted for HEX)
  • Additional engine and transmission sensor packages
  • Instrument panels
  • Electric starting motors - 12V or 24V
  • Air starting motor
  • Dual electric starting motors or combined electric/air
  • Electric fuel priming pump
  • Fuel cooler
  • PTO Drives - V-belt pulley stack, stub shaft
  • Duplex fuel and oil filters
  • Double wall fuel rail