C15 Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

C15 Rear Right
C15 Rear Left
C15 Front Right
C15 Frear Left
Enclosure
Enclosure

Features

  • Cat Generator Set Package

    Cat Generator Set Package

    • Cat generator set packages have been fully prototype tested
    • Accepts 100% block load in one step and meets NFPA 110 loading requirements
    • Conform to ISO 8528-5 steady state and transient response requirements
  • Cat Diesel Engine

    Cat Diesel Engine

    • Reliable, rugged, durable design
    • Field-proven in thousands of applications worldwide
    • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
  • A-Frame Alternator

    A-Frame Alternator

    • Superior motor starting capability minimizes need for oversizing alternator
    • Designed to match performance and output characteristics of Cat diesel engines
    • Robust Class H insulation
  • GCCP 1.3 Control Panel

    GCCP 1.3 Control Panel

    • User-friendly interface and navigation
    • Scalable system to meet a wide range of installation requirement
    • Expansion modules and site-specific programming for specific customer requirements
  • Cooling System

    Cooling System

    • Designed to operate in standard ambient temperatures up to 55°C (131°F)
    • Contact your Cat Dealer for specific ambient and altitude capabilities
  • Certifications

    Certifications

    UL2200 Listed; CSA 22.2; Certification of Compliance – IBC Seismic; Dual IBC & HCAI

  • One Safe Source

    One Safe Source

    • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
    • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
    • Each generator set package is tested before leaving the Caterpillar facility
    • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
  • Worldwide Product Support

    Worldwide Product Support

    • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
    • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Specifications

Units for specifications

Generator Set Specifications

Maximum Rating 500 ekW
Minimum Rating 320 ekW
Emissions/Fuel Strategy Low Fuel, Tier 2, Tier 3, EU Stage IIIA
Voltage 208 to 600 Volts
Frequency 60 Hz
Speed 1800 RPM
Duty Cycle Standby, Prime

Engine Specifications

Engine Model C15 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Bore 5.4 in 137.2 mm
Stroke 6.75 in 171.4 mm
Displacement 927.56 in³ 15.2 l
Compression Ratio 16.1:1
Aspiration Air to Air Aftercooled
Fuel System MEUI
Governor Type Adem™A4

Generator Set Dimensions

Length - Maximum 168.2 in 4273 mm
Width - Maximum 81 in 2058 mm
Height - Maximum 126.3 in 3209 mm

Standard Equipment

Air Inlet

  • Air cleaner

Air System

  • Turbocharger
  • Air cleaner - Non canister disposable paper filter
  • Aftercooler core

Control Panel

  • GCCP 1.3
  • GCCP 1.3 Genset Controller

Cooling

  • Package mounted radiator

Cooling System

  • Caterpillar extended life coolant
  • Fan drive, battery charging alternator drive
  • Radiator and cooling fan with guard
  • Coolant drain line with valve

Exhaust

  • Base, formed steel with single wall integral 8-hour fuel tank
  • Standard open set fuel tank/base supplied
  • Exhaust flange outlet

Fuel

  • Secondary fuel filters
  • Primary fuel filter with integral water separator
  • Fuel priming pump

Fuel System

  • Primary fuel filter w/integral water separator and secondary filter
  • Fuel priming pump
  • Engine fuel transfer pump
  • Flexible fuel lines
  • Fuel cooler

Generator

  • Matched to the performance and output characteristics of Cat engines
  • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
  • IP23 Protection

Power Termination

  • Busbar

Generator and Attachments

  • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
  • Integrated voltage regulator (IVR)
  • Segregated low voltage (AC/DC) wiring panel
  • Optional LC Frame generator - IP23 Protection
  • Power center, IP22
  • A Frame generator - IP21 Protection

Mounting

  • Rubber vibration isolators

Governing System

  • Cat electronic governor (ADEM A4).

Lube System

  • Oil cooler
  • Oil drain valves

Mounting System

  • Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines

Starting/Charging

  • 24 Volt battery with rack and cables
  • 24 volt starting motor
  • Batteries

General

  • Engine and alternator pre paint, Caterpillar yellow
  • Paint - Caterpillar yellow except rails and radiators gloss black

Optional Equipment

Air Inlet System

  • Single element air cleaner
  • Dual element air cleaner

Exhaust

  • Industrial, residential, critical mufflers

Certifications

  • EU Certificate of Conformance (CE)
  • Global certification for CIS

Circuit breakers

  • Shunt trip for IEC circuit breaker
  • Padlockable circuit breaker device
  • 4 Pole (IEC-100% rated) Circuit breakers - Motorised
  • Auxiliary contacts, circuit breaker
  • 3 Pole (IEC-100% rated) Circuit breakers - Motorised
  • 3 Pole (IEC-100% rated) Circuit breakers - Package mounted
  • 4 Pole (IEC-100% rated) Circuit breakers - Package mounted
  • Power terminal strip

Generator

  • Oversize and premium generators
  • Anti-condensation heater
  • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)

Power Termination

  • Circuit breakers, UL listed
  • Circuit breakers, IEC compliant

Control Panels

  • GCCP 1.4
  • Volt free contacts
  • Local annunciator
  • Remote annunciator module
  • Local alarm horn
  • Oil temperature displays
  • Protective devices: Earth fault relay ; Earth leakage Ground fault relay ; Overload shutdown via breaker ; Low fuel level alarm ; Low fuel level shutdown ; High fuel level alarm ; Fuel level sensor

Starting/Charging

  • Jacket water heater
  • Charging alternator
  • Heavy duty starting system
  • Battery chargers
  • Oversize batteries

Cooling System

  • Stone guards
  • Radiator duct flange
  • Low coolant temperature alarm

Enclosures

  • Sound attenuated enclosures
  • High ambient sound attenuated enclosures

General

  • Sound attenuated, weather protective or high ambient weather protective enclosure
  • CSA Certification
  • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
  • EEC Declaration of Conformity
  • Integral & sub-base UL listed dual wall fuel tanks
  • Automatic transfer switches (ATS)
  • Single or dual wall sub-base fuel tanks
  • The following options are based on regional and product configuration:
  • EU Certificate of Conformance (CE)
  • Single or dual wall integral fuel tanks
  • Narrow, wide or skid base
  • UL 2200 package

Exhaust System

  • Engine mounted muffler
  • End in/end out mufflers - 10, 25 and 35 dBA attenuation
  • 6 and 8 inch elbow kit
  • Manifold and turbocharger guards
  • Flexible exhaust fittings
  • 6 and 8 inch flange GP

Fuel System

  • Manual fuel transfer pump
  • Dual wall fuel tank base
  • Fuel transfer system controls

Generator and Attachments

  • Space heaters
  • Permanent magnet excitation (PMG) generator
  • Ingress protection
  • LC frame generator
  • Oversize A Frame generator
  • LC frame CIP generator
  • CIP A Frame generator
  • Oversize LC frame generator

Lube System

  • Manual sump pump

Mounting System

  • Narrow skid base - replaces standard fuel tank base

Special Test / Reports

  • PGS Test report @ 1.0 power factor
  • PGS Test report @ 0.8 power factor

Starting / Charging System

  • 5 Amp single Battery charger
  • Battery disconnect switch
  • Jacket water heater
C15 Rear Left