CG260 Gas Generator Set
CG260-12

Features

  • High Reliability

    High Reliability

    • Anti-knock control and cylinder balancing protect the engine from overload and ensure reliable operation
    • State-of-the-art turbocharger A140 with Wastegate ensures full performance even under high temperatures and higher altitudes
    • Higher reliability and lower maintenance costs due to open combustion chamber technology
  • High Availability, High Profitability

    High Availability, High Profitability

    • Miller valve timing and optimized compression ratios ensure high efficiency and low fuels costs
    • More profit for your plant
    • Long maintenance intervals and general overhaul only after 80,000 oh allow an operation of 10 years without general overhaul
    • Flexible fields of application also with fluctuating gas qualities due to Total Electronic Management (TEM)
  • Optimized Lubrication Consumption

    Optimized Lubrication Consumption

    • Savings of up to 4,000 liters of lube oil per year compared to comparable gensets
    • Improved components reduce lube oil consumption
    • Lower operating costs due to 30% lower lube oil consumption in comparison to similar products

Specifications

Units for specifications

Generator Set Specifications

Continuous Rating 3333 / 3000 ekW @1.0pf
Fuel Type Natural Gas, Coal Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency 43.90%
Frequency 50Hz / 60 Hz
RPM 1000 / 900 rpm

Engine Specifications

Engine Model CG260-12
Displacement 12443 in³ 203.9 l
Aspiration TA
Bore 10.2 in 260 mm
Stroke 12.6 in 320 mm

Generator Set Dimensions

Length 315 in 8000 mm
Width 105 in 2660 mm
Height 110 in 2794 mm
Dry Weight - Genset 89617 lb 40649.6 kg

Standard Equipment

Air Inlet

  • One-element single-stage air cleaner with enclosure and sevice indicator
  • Turbocharger with a water-cooled bearing case for all cylinder

Control Panels

  • TEM (Total Electronic Management)

Cooling

  • flange connections for JW inlet and outlet
  • Jacket water and SCAC thermostats
  • Electrical jacket water and aftercooler coolant pump

Exhaust

  • Exhaust waste gate for the CG260-12
  • Closed crankcase ventilation system

Fuel system

  • Independently controlled cylinder monitoring and ignition system
  • Electronic fuel metering valve
  • Pre-chamber spark plugs

Generator

  • Busbar connections
  • Closed-coupled generator result in no torque transmission to the base frame
  • Anti-condensation space heater
  • Reactive droop
  • 3-phase sensing and KVAR/PF control
  • Grid code generator
  • Winding temperature detectors

Starting/Charging

  • Compressed air engine start

General

  • Crankshaft vibration damper and guard

Optional Equipment

Cooling

  • CHP skid

Grid Code Compliance

  • 50Hz: Germany, Belgium, Great Britain, Italy, Poland, and Netherlands
CG260-12

Documents