CG170B-12 Gas Generator Set
CG170B-12
CG170B-12 Front Right View
CG170B-12 Rear Right View
CG170B-12 Rear Left View
CG170B-12 Front Left View
CG170B_V12

Features

  • High Efficiency, Lower Operating Costs

    High Efficiency, Lower Operating Costs

    • Up to 45% electrical efficiency with Natural Gas
    • 43.6% electrical efficiency with biogas
    • Electrical output up to 1,380 kWel
    • Reduced vibration and stress on components
  • Compact Size, High Profitability

    • Compact design that delivers up to 18% more power output at the same size as its predecessor
    • Long maintenance intervals (up to 80,000 hours)
    • Available in different applications, such as natural gas, biogas, wellhead- and propane gas operation
    • Maximum flexibility through different engine variants
  • Optimized Lubrication Consumption

    Optimized Lubrication Consumption

    • Consumes ~0.15g/kWh
    • Reduced lube oil temperature through better cooling performance
    • Savings of up to 3,000 liters of lube oil per year compared to comparable gensets

Specifications

Units for specifications

Generator Set Specifications

Continuous Rating 1380 ekW @1.0pf
Fuel Type Natural Gas, Biogas, Coal Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency 45.00%
Maximum Standby Rating 1380
Frequency 50 Hz
RPM 1500 rpm

Engine Specifications

Engine Model CG170B-12
Aspiration TA
Bore 6.7 in 170 mm
Stroke 7.7 in 195 mm

Generator Set Dimensions

Length 200 in 5080 mm
Width 67 in 1710 mm
Height 86 in 2190 mm
Dry Weight - Genset 28440 lb 12900 kg

Standard Equipment

Air Inlet

  • One-element single-stage air cleaner with enclosure and sevice indicator
  • Turbocharger with a water-cooled bearing case for all cylinder

Control Panels

  • TPEM (Total Plant & Energy Management System)

Cooling

  • Jacket water and SCAC thermostats
  • ANSI/DN customer flange connections for JW inlet and outlet
  • Electrical jacket water and aftercooler coolant pump
  • flange connections for JW inlet and outlet

Exhaust

  • Exhaust waste gate for the CG170B-12
  • PEARL/Low resistence exhaust system
  • Closed crankcase ventilation system

Fuel system

  • Pre-chamber spark plugs
  • Electronic fuel metering valve
  • Independently controlled cylinder monitoring and ignition system

Generator

  • Reactive droop
  • closed-coupled generator result in no torque transmission to the base frame
  • Winding temperature detectors
  • Busbar connections
  • grid code generator
  • Anti-condensation space heater
  • 3-phase sensing and KVAR/PF control

Starting/Charging

  • 24V starting motors
  • Battery disconnect switch

General

  • Crankshaft vibration damper and guard

Optional Equipment

Cooling

  • CHP skid

Grid Code Compliance

  • 50Hz: Germany, Belgium, Great Britain, Italy, Poland, and Netherlands

Videos

  • Cat® CG170B Gas Generator Set
CG170B-12 Front Right View