C13 Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

C13 NACD Diesel Generator Set Right Front
C13 NACD Diesel Generator Set Left
C13 NACD Diesel Generator Set Top
C13 NACD Diesel Generator Set Rear
Enclosure
Enclosure

Features

  • Cat Generator Set Package

    Cat Generator Set Package

    • Cat generator set packages have been fully prototype tested
    • Accepts 100% block load in one step and meets NFPA 110 loading requirements
    • Conform to ISO 8528-5 steady state and transient response requirements
  • Cat Diesel Engine

    Cat Diesel Engine

    • Reliable, rugged, durable design
    • Field-proven in thousands of applications worldwide
    • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
  • A-Frame Alternator

    A-Frame Alternator

    • Superior motor starting capability minimizes need for oversizing alternator
    • Designed to match performance and output characteristics of Cat diesel engines
    • Robust Class H insulation
  • GCCP 1.3 Control Panel

    GCCP 1.3 Control Panel

    • User-friendly interface and navigation
    • Scalable system to meet a wide range of installation requirement
    • Expansion modules and site-specific programming for specific customer requirements
  • Cooling System

    Cooling System

    • Designed to operate in standard ambient temperatures up to 55°C (131°F)
    • Contact your Cat Dealer for specific ambient and altitude capabilities
  • Certifications

    Certifications

    UL2200 Listed; CSA 22.2; Certification of Compliance – IBC Seismic; Dual IBC & HCAI

  • One Safe Source

    One Safe Source

    • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
    • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
    • Each generator set package is tested before leaving the Caterpillar facility
    • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
  • World Wide Product Support

    World Wide Product Support

    • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
    • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Specifications

Units for specifications

Generator Set Specifications

Maximum Rating 400 ekW
Minimum Rating 320 ekW
Emissions/Fuel Strategy EPA Stationary Emerg Use
Voltage 208 to 600 Volts
Frequency 60 Hz
Speed 1800 rpm
Duty Cycle Standby, Prime

Engine Specifications

Engine Model C13 ACERT In-line 6, 4-cycle diesel
Bore 5.12 in 130 mm
Stroke 6.2 in 157 mm
Displacement 763 in³ 12.5 B
Compression Ratio 16.3:1
Aspiration Turbocharged Air to Air Aftercooled
Fuel System MEUI
Governor Type Adem™A4

Generator Set Dimensions

Length - Maximum 186.7 in 4743 mm
Width - Maximum 79.3 in 2014 mm
Height - Maximum 84 in 2133 mm

Standard Equipment

Air Inlet System

  • Turbocharger
  • Aftercooler core
  • Air cleaner; light duty with disposable paper filter

Starting / Charging

  • Charging alternator
  • 24 Volt electric starting motor

Control Panel

  • GCCP 1.3

Control System Controller

  • GCCP 1.3

Cooling System

  • Fan drive, battery charging alternator drive
  • Caterpillar extended life coolant
  • Coolant drain line with valve
  • Radiator and cooling fan with guard

Certification

  • EPA stationary emergency use

Exhaust System

  • Stainless steel exhaust flex, gaskets, raincap & SAE exhaust flange for customer use - shipped loose

Base / Fuel Tank

  • Audio and visual fuel alarm

Fuel System

  • Standard open set fuel tank/base supplied
  • Base, formed steel with single wall integral 8-hour fuel tank

Protection

  • Safety shutoff - Overspeed
  • Safety shutoff - Low oil pressure
  • Safety shutoff - High water temperature

Generator and Attachments

  • Segregated low voltage (AC/DC) wiring panel
  • Power center, IP22
  • A Frame generator - IP21 Protection
  • Integrated voltage regulator (IVR)
  • Optional LC Frame generator - IP23 Protection
  • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre

Governing System

  • Cat electronic governor (ADEM A4)

Lube System

  • Oil cooler
  • Oil drain valves
  • Lubricating oil

Mounting System

  • Includes lifting provisions and termination points for coolant and lube oil drain lines
  • Captive linear vibration isolators between base and engine-generator

Starting / Charging System

  • 24V battery with rack and cables

General

  • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

European Certificates

  • Global Certification for CIS
  • EU Certificate of Conformance (CE)

Air Inlet System

  • Single element air cleaner
  • Dual element air cleaner

Circuit breakers

  • Padlockable circuit breaker device
  • 3 Pole (IEC-100% rated) Circuit breaker
  • Shunt trip for IEC circuit breaker
  • 4 Pole (IEC-100% rated) Circuit breaker - Motorised
  • Circuit breaker (IEC) Auxiliary contacts
  • 4 Pole (IEC-100% rated) Circuit breaker
  • Power terminal strip
  • 3 Pole (IEC-100% rated) Circuit breakers - Motorised

Control Panels

  • Control panel protective devices: Earth fault relay ; Earth leakage ground fault ; Overload shutdown via breaker ; Low fuel level alarm ; Low fuel level shutdown ; High fuel level alarm ; Fuel level sensor
  • GCCP 1.4
  • Volt free contacts
  • Local alarm modules: Local annunciator
  • Remote annunciator module

Cooling System

  • Radiator duct flange
  • Stone guards
  • Low coolant temperature alarm

Enclosures

  • Sound attenuated enclosures
  • High ambient sound attenuated enclosures

Exhaust System

  • Flexible 8 inch exhaust fittings
  • Mufflers - End in/end out
  • 10, 25 and 35 dBA attenuation
  • 6 and 8 inch elbow kit
  • 6 and 8 inch flange GP

Fuel System

  • Fuel transfer system controls
  • Manual fuel transfer pump
  • Integral dual wall fuel tank base

Generator and Attachments

  • LC frame generator
  • LC CIP generator
  • Space heaters
  • Ingress protection
  • A Frame oversize generator
  • Permanent magnet excitation (PMG) generator
  • A Frame CIP generator

Lube System

  • Manual sump pump

Mounting System

  • Narrow skid base

starting / Charging System

  • Battery disconnect switch
  • Jacket water heater
  • 5 Amp single Battery charger