Skip to main content Skip to navigation
Ag Agriculture Blog IconBehind the Scenes Blog IconConstruction Blog IconEquipment Maintenance Blog Icon Power Systems Blog Icon Thumbs Down Thumbs Up! Small Business Blog IconTachnology Blog Icon Constructioncontrol-smallcost-smallefficiency-smallflexibility-smallHoursHours Location HoursMapMapMenu AgMenu AttachmentsMenu BlogMenu CareersMenu ChecklistMenu ConstructionMenu MaintenanceMenu NewMenu PowerMenu RebuildsMenu RentMenu ServiceMenu TechnologyMenu TestimonialsMenu Training Menu Truck Menu UsedNewArtboard 1Parts Phone Phone PhonePower Systemsproductivity-smallRentalRepSafetyServiceSpecialsTechtestimonial-iconToolsTrainingTruckUsed

Cat

DE110 GC Generator Set (60 Hz)

Maximum Rating

100 ekW

Minimum Rating

100 ekW

Emissions/Fuel Strategy

Non Regulated

Overview

Producing reliable power of 100 ekW at 60 Hz, our DE110 GC diesel generator set is designed to meet ISO 8528-5 transient response requirements.

Photos

360° View

Exterior

Showroom

DE110 GC, Virtual Product Tour

Features

Specifications

  • Generator Set Specifications
    Spec Value
    Maximum Rating 100 ekW
    Minimum Rating 100 ekW
    Emissions/Fuel Strategy Non Regulated
    Voltage 220 to 480 Volts
    Frequency 60 Hz
    Speed 1800 rpm
    Duty Cycle Standby
  • Engine Specifications
    Spec Value
    Engine Model C4.4, In-line 4, 4-cycle diesel
    Bore 4.1 in
    Stroke 5 in
    Displacement 268.5 in
    Compression Ratio 18.23:1
    Aspiration Turbocharged Air To Air Charge Cooled
    Fuel System Inline
    Governor Type Mechanical
  • Generator Set Dimensions
    Spec Value
    Length - Maximum 108.1 in
    Width - Maximum 39.3 in
    Height - Maximum 58.1 in
    Dry Weight - Genset (maximum) 2932 lb

Standard Equipment

Engine

  • C4.4, Inline 4 cylinder, 4 stroke diesel

Alternator

  • A Frame standard alternator

Fuel Storage

  • Single wall 8 hour fuel tank

Genset Control

  • GCCP 1.1

Governor

  • Mechanical governor

Enclosure

  • Cat GC enclosure

Air, Cooling & Exhaust

  • Enclosure silencer

General

  • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

Certification

  • Australia, CIS, Gulf Certification
  • Certificate of Conformance 13

Auxiliary Supply Voltage

  • 120V

Alternator Requirements

  • Space heater

Fuel Storage

  • Dual wall 8 hour fuel tank
  • Low fuel level shutdown
  • Single wall tank with containment
  • Low fuel level alarm
  • High fuel level alarm

Genset Control

  • Volt free contacts for genset running
  • Emergency stop with key
  • Battery charger
  • Earth fault
  • USB to RS485 Communications device
  • Panel mounted audible alarm
  • Earth leakage
  • Volt free contacts for common alarm
  • USB to RS485 Communications device
  • Coolant heater
  • Battery
  • Low coolant level shutdown
  • Standby Pack (Smart Jacket water heater, Battery charger)

Circuit breaker

  • 3 Pole Circuit breaker 125A
  • 3 Pole Circuit breaker 160A
  • 3 Pole Circuit breaker 200A
  • 3 Pole Circuit breaker 250A
  • 4 Pole Circuit breaker 160A
  • 4 Pole Circuit breaker 125A
  • 3 Pole Circuit breaker 400A
  • 4 Pole Circuit breaker 200A
  • 4 Pole Circuit breaker 250A
  • Circuit breaker padlock
  • 4 Pole Circuit breaker 400A
  • Neutral earth link
  • Overload via alarm switch on breaker

Testing & Packaging

  • PGS Test report @ 1.0 power factor
  • PGS Test report @ 0.8PF