Cat EGP Switchgear
- Configuration
 - Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie and load breakers in conjunction with downstream transfer switches for standby or emergency applications
 - Modes of Operation
 - Multi-unit Island and multi-unit standby mode with optional redundant controls and components.
 - Application
 - LV and MV (208V - 38 kV)
 
EGP (Emergency Generator Paralleling) switchgear is used for paralleling multiple generators that are not directly connected to a utility source.
Features
- 
											
EGP Switchgear
- High Speed Supervisory Network
 - Automatic Start/Stop
 - Automatic “Dead Bus” Coordination
 - Programmable Load Shed / Load Add Functions
 - Networked Engine Communications
 - Generator Protection
 - Engine Tuning
 - Mode Selection
 - Selectable Auto/ Manual Control
 - Password Protection for Protective Settings and Setup
 - Load/No Load Test
 - Touch Screen (HMI) Display
 - NFPA 99/110 Compliant Alarm
 - Annunciation with Audible Horn
 - Engine Control mimic Screen with gauges for RPM, DC Battery Voltage oil Pressure, Engine Coolant temperature, Engine Hours, Number of starts
 
 
Specifications
Units for specifications
Technical Summary
| Configuration | Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie and load breakers in conjunction with downstream transfer switches for standby or emergency applications | 
|---|---|
| Modes of Operation | Multi-unit Island and multi-unit standby mode with optional redundant controls and components. | 
| Application | LV and MV (208V - 38 kV) | 
Generator Protective Devices
| ANSI Protective Devices | 15/25, 27/59, 81 O/U, 32, 40, 50, 51 | 
|---|
Environmental Parameters
| Certifications | IBC, CBC, UBC & OSHPD Certified | 
|---|---|
| Control Panel Enclosure | NEMA 1 or NEMA 3R Freestanding Construction | 
| Operating Temperature | 0°C to 50°C | 
| Storage Temperature | -20°C to +60°C | 
| Low Voltage Standards | NEMA SG-5, CSA, ANSI C37.51, ANSI C37.20.1, UL 1558 or UL 891, NFPA 110, NFPA 99 and NFPA 70 | 
| Medium Voltage Standards | NEMA SG-5, ANSI / IEEE C37.20.2, CSA-C22.2 No. 31-M89, EEMAC G8-3.2, NFPA 70, NFPA 99 and NFPA 1110 | 
Standard Equipment
EGP Switchgear
- Choice of 19” Surface Acoustic Wave Color or 15” Resistive Color Touchscreen
 - Emergency Stop Button for each generator
 - Instant Auto Switch
 - Generator Demand Priority Control
 - Audible Alarm & Horn Silence Button
 - Circuit Breaker Control Switch with Indicators
 
Optional Equipment
Data Table Interface
- * Accomodates interface with a building management system for monitoring all system parameters via Modbus RTU or TCP
 
Supplemental Hardware Synchronization check relay (ANSI 25 Device)
- * Provides additional discrete synchronization protection
 
Remote Power Monitoring System
- * To monitor breaker status, alarms, metering and other operating parameters