Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Features
- 
											
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
 - Accepts 100% block load in one step and meets NFPA 110 loading requirements
 - Conform to ISO 8528-5 steady state and transient response requirements
 
 - 
											
Cat Diesel Engine
- Reliable, rugged, durable design
 - Field-proven in thousands of applications worldwide
 - Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
 
 - 
											
SR5 Alternator
- Superior motor starting capability minimizes need for oversizing alternator
 - Designed to match performance and output characteristics of Cat diesel engines
 - Robust Class H insulation
 
 - 
											
Cat ECS Control Panel
- User-friendly interface and navigation
 - Scalable system to meet a wide range of installation requirement
 - Expansion modules and site-specific programming for specific customer requirements
 
 - 
											
Cooling System
- Designed to operate in standard ambient temperatures up to 50�C (122�F)
 - Contact your Cat Dealer for specific ambient and altitude capabilities
 
 - 
											
One Safe Source
- Components used in the generator set are selected at the design stage to provide optimum package performance
 - The generator set is fully assembled at a Caterpillar facility following our quality guidelines
 - Each generator set package is tested before leaving the Caterpillar facility
 - Cat product support, including dealer service, parts and warranty covers the entire Cat power system
 
 - 
											
Worldwide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
 - Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
 
 
Specifications
Units for specifications
Generator Set Specifications
| Prime Power Rating | 1825 ekW | 
|---|---|
| Continuous Rating | 1640 ekW | 
| Emissions/Fuel Strategy | Low Fuel Consumption | 
| Voltage | 380 to 13800 Volts | 
| Frequency | 60 Hz | 
| Speed | 1800 rpm | 
| Duty Cycle | Prime, Continuous | 
| Maximum Rating | 1825 ekW | 
| Minimum Rating | 1640 ekW | 
Engine Specifications
| Engine Model | 3516B TA, V-16, 4-Stroke Water-Cooled Diesel | 
|---|---|
| Bore | 6.69 in 170 mm | 
| Stroke | 7.48 in 190 mm | 
| Displacement | 4210.64 in 69 l | 
| Compression Ratio | 14.0:1 | 
| Aspiration | TA | 
| Fuel System | Electronic unit injection | 
| Governor Type | Adem™4 | 
Generator Set Dimensions
| Length - Minimum | 264.3 in 6714 mm | 
|---|---|
| Length - Maximum | 264.3 in 6714 mm | 
| Width - Minimum | 90.1 in 2288 mm | 
| Width - Maximum | 90.1 in 2288 mm | 
| Height - Minimum | 94.1 in 2391 mm | 
| Height - Maximum | 94.1 in 2391 mm | 
| Dry Weight - Genset (minimum) | 33300 lb 15135 kg | 
| Dry Weight - Genset (maximum) | 33300 lb 15135 kg | 
Standard Equipment
Air Inlet System
- Air cleaner, single element canister type
 
Cooling
- Package mounted radiator
 
Exhaust
- Exhaust flange outlet
 
Fuel
- Primary fuel filter with integral water separator
 - Secondary fuel filters
 
Control System
- Generator set packages include Caterpillars voltage regulator
 - 6 Customer programmable digital inputs
 - Controls:
 - Low coolant temperature
 - Auto/start/stop control
 - Low coolant level
 - Customer data link (Modbus RTU)
 - PLC functionality
 - kVA (per phase, average & percent)
 - Reverse power (kW) (32)
 - Alarm acknowledge
 - kW (per phase, average & percent)
 - kW-hr (total)
 - Lamp test
 - RPM
 - Volts (L-L & L-N), frequency (Hz)
 - Generator phase sequence
 - Operating hours
 - kVAr-hr (total)
 - True RMS AC metering, 3-phase, +/-2% accuracy
 - Over/under frequency (81 o/u)
 - Accessory module data link
 - Number of I/O varies on options selected
 - High coolant temperature
 - Overspeed
 - 1 Programmable digital outputs
 - Regulator (IVR) - IVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter
 - DC volts
 - Reverse reactive power (kVAr) (32RV)
 - Amps (per phase & average)
 - Oil pressure (psi, kPa or bar)
 - Coolant temperature
 - Failure to start (overcrank)
 - 3 Analog inputs
 - Power factor (per phase & average)
 - EMCP 4.3
 - kVAr (per phase, average & percent)
 - Cat connect
 - Engine cool-down timer
 - 1 Programmable relay outputs (Form C)
 - Environmental sealed front face
 - Warning/shutdown with common LED indication of shutdowns for:
 - 24 Volt DC operation
 - Over/under voltage (27/59)
 - Emergency stop pushbutton
 - Limiter and exciter diode monitor
 - Generator mounted - rear facing
 - Digital indication for:
 - Text alarm/event descriptions
 - Customizable screens
 - Load histogram feature
 - Emergency stop
 - Serial annunciator module data link
 - Programmable protective relaying functions:
 - Low oil pressure
 - Communications:
 - Speed adjust
 - Engine cycle crank
 - 4 Programmable relay outputs (Form A)
 - Overcurrent (50/51)
 
Power Termination
- Busbar
 
Control Panel
- Cat ECS Genset controller
 
Cooling System
- Package mounted radiator
 
Exhaust System
- Dry exhaust manifold
 - Flanged faced outlet(s)
 
Fuel System
- Fuel cooler; not included with packages without radiator
 - Flexible fuel lines - shipped loose
 - Secondary fuel filters
 - Fuel priming pump
 
General
- SAE standard rotation
 - Flywheel and Flywheel housing-SAE No. 00
 - Paint - Caterpillar yellow except rails and radiators gloss black
 - RH service
 
Generators and Attachments
- Matched to the performance and output characteristics of Cat engines
 - Random wound
 - IP23 Protection
 - Anti-condensation space heater
 - 3 Phase brushless, Salient pole
 - HV:
 - Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
 - LV
 - NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby) - 60 Hz models: NEMA standard hole pattern
 - 6 Lead
 - Form wound
 - Busbar connections, right side extension box, bottom cable entry - 60 Hz models: NEMA standard hole pattern
 - Winding temperature detectors
 - MV:
 - NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
 
Governing System
- ADEM A3
 
Lube System
- Oil drain lines and valve
 - Lubricating oil
 - Integral lube Oil cooler
 - Oil filter, filler and dipstick
 - Fumes disposal
 - Gear type lube oil pump
 
Mounting System
- Rails - Engine/generator/radiator mounting.
 - Rubber anti-vibration mounts - shipped loose
 - Anti-vibration mounts (shipped loose)
 
Starting System
- Battery disconnect switch
 - 24 Volt electric starting motor
 - 45 Amp Charging alternator
 - Battery and battery rack w/cables
 
Optional Equipment
Exhaust
- Exhaust mufflers
 
Air Inlet System
- Standard ambient radiators
 - Dual element air cleaner
 - Standard ambient ATAAC radiators
 - Single element filter
 - Optional radiator arrangements
 
Generator
- Anti-condensation heater
 - Permanent magnet excitation (PMG)
 - Oversize and premium generators
 - Internal excitation (IE)
 
Control Panels
- EMCP 4.4
 - Load share module
 - Digital I/O module
 - Generator main terminal box
 - Remote monitoring software
 - Vandal proof panel cover
 - Generator temperature monitoring & protection
 - Empty upper box
 - Cable Shroud
 - Annunciator - local
 - Digital I/O module
 - Annunciator - remote
 - Side extension box
 
Cooling System
- Coolant
 - Water level switch gauges
 
Crankcase Systems
- No explosion relief valves
 - Explosion relief valves
 - Crankcase ventilation systems
 - Crankcase protection groups:
 
Mounting
- Rubber anti-vibration mounts
 - IBC isolators
 
Exhaust System
- Flange and exhaust expanders
 - Flexible fittings
 - Tier 4 lean emissions moDual
 - Flanges
 - Elean emission parts
 - Tier 4 dosing cabinet
 - Exhaust offset
 - Mufflers
 - Tier 4 clean emission MOD kits
 - Y Adapters
 - Elbows>
 
Starting/Charging
- Oversize batteries
 - Charging alternator
 - Heavy duty starting system
 - Jacket water heater
 - Battery chargers
 
General
- CSA Certification
 - EEC Declaration of Conformity
 - Automatic transfer switches (ATS)
 - UL 2200 package
 - Integral & sub-base UL listed dual wall fuel tanks
 - EU Certificate of Conformance (CE)
 - Integral & sub-base fuel tanks
 - Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
 - Enclosures: Sound attenuated, weather protective
 - The following options are based on regional and product configuration:
 
Extended Service Coverage
- Platinum, Silver and Gold coverage
 
Fuel System
- Primary fuel filter
 - Fuel priming pumps (Tier 4)
 - Gas fuel filter
 
Generators and Attachments
- Generator conversions
 - Hi voltage optional attachments
 - 2700 Frame - 6300, 6600, 6900 Volts, 3 Phase 1800 RPM, FW, PM, No. of leads = 6, Pitch = .6667
 - 1600 Frame - 380, 440, 480, 600 Volts, 3 Phase 1800 RPM, RW, PM, No. of leads = 6, Pitch = .6667
 - Generators high voltage
 - Differential current transformers
 - 1600 Frame - 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM ,FW, PM, No. of leads = 6, Pitch = .6667
 - 1600 Frame - 380, 440, 480, 600 Volts, 3 Phase 1800 RPM, RW, IE, No. of leads = 6, Pitch = .6667
 - Alternator air cleaner
 - 1800 Frame
 - Space heater kit
 - 3000 Frame - 12470, 13200, 13800 Volts, 3 Phase 1800 RPM, FW, PM, No. of leads = 6, Pitch = .6667
 
Instrumentation
- Pyrometer and termocouples
 
Lube System
- Oil level regulator
 - Prelube pump groups
 - Lube oil in standard sump
 
Mounting System
- IBC vibration isolators
 - Puck style low efficiency isolators
 - Spring type vibration isolators
 
Power Connections
- Center post busbars
 - Cable entry - rear
 - Rear power connections
 - Cable entry - right side
 - Cable entry - left side
 - Grounding groups
 - Neutral ground connections
 - Right side power connections
 - left side power connections
 
Power Termination
- Circuit breakers - LV Packages
 - 2000, 2500, 3200 Amp, 4 Pole, IEC rated Circuit breakers
 - Circuit breakers, IEC compliant
 - Circuit breakers, UL listed
 - 1600, 2000, 2500, 3000 and 4000 Amp, 3 Pole, UL-100% rated Circuit breakers
 - 2000, 2500, 3200 Amp, 3 Pole, IEC rated Circuit breakers
 
Special Tests / Reports
- Generator set report
 - PGS Test report @ 0.8 power factor
 - Fuel consumption test
 - Torsional vibration analysis
 - Seismic Certifications
 - PGS Test report @ 1.0 power factor
 - Standard engine test
 - OSPD Certification
 
Starting / Charging
- 10, 20, 35 Amp Battery chargers
 - Engine barring device
 - Batteries, racks and cables
 - Jacket water heaters
 - Air starting motors with control and silencer
 - Electric starting motors
 - Starter cover
 - 50 Amp NFPA battery charger
 - Air pressure regulator
 
Videos
- 
											
DGB Video