Producing reliable power of 200 ekW at 60 Hz, our D200 GC diesel generator set is designed to meet ISO 8528-5 transient response requirements.
Cat
D200 GC Generator Set
Overview
Photos
360° View
Exterior
Interior
360° Interior view. Double click on the image to zoom in on any area of the product.
Showroom
D200 GC, Virtual Product Tour
Features
Specifications
-
Generator Set Specifications
Spec Value Maximum Rating 200 ekW Minimum Rating 200 ekW Emissions/Fuel Strategy U.S. EPA Cert., Tier 3 Voltage 208 to 600 Volts Frequency 60 Hz Speed 1800 rpm Duty Cycle Standby -
Engine Specifications
Spec Value Engine Model C7.1 I-6, 4-Cycle Diesel Bore 4.1 in Stroke 5.31 in Displacement 428 in³ Compression Ratio 16.7:1 Aspiration Turbocharged, Air to Air Aftercooled Fuel System Electronic, Common Rail Governor Type ADEM™A4 -
Generator Set Dimensions
Spec Value Length - Maximum 103.7 in Width - Maximum 51.2 in Height - Maximum 58.7 in Dry Weight - Genset (maximum) 3917 lb
Standard Equipment
Air Inlet System
- Air cleaner; light duty with disposable element
Control Panels
- GCCP 1.2 Control panel
Cooling System
- Coolant drain line with valves
- Radiator and cooling fan with guards
- Caterpillar extended life coolant
- Fan drive, battery charging alternator drive
Generator and Generator Attachments
- Segregated low voltage (AC/DC) wiring panel
- Voltage regulator (single phase sensing)
- Circuit breaker, IEC, 3 pole, mounted in tower panel
- Tower panel, IP22, bottom cable entry
- 12 Leads
- IP23 Protection
Exhaust System
- Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
Fuel System
- Standard open set fuel tank/base supplied
- Base, formed steel with single wall integral 24-hour fuel tank
Lube System
- Oil drain line with valve
- Lubricating oil
Mounting System
- Captive linear vibration isolators between base and engine-generator
- Includes lifting provision and drag points
- Termination points for coolant and lube oil drain lines
Starting / Charging System
- 24V battery with rack and cables
Governing System
- Mechanical and electrical governing system - model dependent
General
- Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment
Alternator System
- Quatrature droop king
- Permanent magnet excitation (PMG)
- R Frame auxiliary winding: R2273L4 SE aux alt 07, aux alt 08 and aux alt 10
- Alternator removal
- Anti-condensation heater
- 3 Phase sensing
- Optional LC Frame alternator with coastal insulation protection
Circuit breakers
- Padlockable breaker device
- 4 Pole 250A, 400A and 630A Circuit breakers
Control Panel Options
- Earth leakage (2 wire only)
- Panel mounted audible alarm
- Speed adjust potentiometer
- Overload shutdown via breaker
- Emergency stop with key
- Earth fault (2 wire only)
- Control panel heater
- Battery charger
- Speed adjust contacts
- Volt free contacts
Control System
- Volt free contacts for generator set running
- GCCP 1.2
- Volt free contacts for common alarm
- Static battery charger
Cooling System
- Low coolant temperature
- Coolant heater
- Low coolant level shutdown
Enclosures
- Sound attenuated level 2 enclosure
Mounting Options
- Silencer installation kit
- Battery removal
- Electronic governor
- Industrial silencer removal
- Residential silencer
Fuel Systems
- Open set narrow tankbase
- Low fuel level shutdown
- Low fuel level alarm
- Compact skidbase for open sets
- DEFRA bunded fuel tank
- High fuel level alarm
- Skidbase for CALG enclosure sets
Test Reports
- PGS Test report @ 1.0 power factor
- PGS Test report @ 0.8 power factor
General
- Stone guards/radiator trans flange
Global Certifications
- Certification for CIS
Power Termination
- Circuit breaker, IEC, 4 pole
Accessories / Miscellaneous
- Packing case - canopied set
- Packing case - compact set
Sign up for Ziegler CAT emails